FHWA NBI 2024 Inspection record Public-domain dataset

FDR 591

Carrying FDR 591 over COAL CREEK

9.1 MI ON FDR 591, San Juan, Colorado

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
21 t Inventory load rating

Bridge Snapshot: FDR 591

The FDR 591 bridge in San Juan, Colorado carries FDR 591 over COAL CREEK. It was built in 1937, making it 89 years old today. It was last reconstructed in 1957, extending its service life. The structure is built primarily of steel and spans 1 section, stretching 7.6 meters (25 feet) end to end. Daily traffic averages 37 vehicles, placing it in the lower-traffic tier of Colorado bridges. It is owned and maintained by U.S. Forest Service.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. All reported major components score above the Poor range. Its NBI inventory load rating is 20.9 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How FDR 591 compares

▼ 16.2
Load rating vs Colorado average (37.1 t)
Bottom 11%
Lower load rating than 89% of Colorado bridges
13
Bridges in San Juan · 1 in Poor condition
FDR 591 20.9 t
Colorado average 37.1 t

Live comparison across Colorado.

Historical Sufficiency Rating

PlainBridge-computed
69.2 / 100 - historical 50–79.9 band
Structural adequacy /55
42.3
Serviceability /30
13.0
Essentiality /15
14.9
Special reductions
−1.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
20.9 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1937
Last Reconstructed
1957
Material
Steel
Number of Spans
1
Structure Length
7.6 m (25 ft)
Deck Width
5.0 m (16 ft)
Owner
U.S. Forest Service
Avg Daily Traffic
37 vehicles/day
Structure Number
021301000001142

Condition Analysis

  • At 7/9, the deck (driving surface) is in good shape and shows no significant wear.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • At 7/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether FDR 591 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare FDR 591 against other structures in San Juan and across Colorado. Colorado bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for FDR 591?

FDR 591 in San Juan, Colorado has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is FDR 591 inspected?

FDR 591's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 37 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. FDR 591 is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for FDR 591?

FDR 591 has an NBI inventory load rating of 20.9 metric tons.

Who is responsible for maintaining FDR 591?

FDR 591 is owned and maintained by U.S. Forest Service.

How old is FDR 591 and does age affect safety?

FDR 591 was built in 1937, making it 89 years old and last reconstructed in 1957.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.