FHWA NBI 2024 Inspection record Public-domain dataset

SE GREEN OAKS WB

Carrying SE GREEN OAKS WB over TRIBUTARY OF FISH CREEK

0.3 MI E OF NEW YORK AVE, Tarrant, Texas

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
41 t Inventory load rating

Bridge Snapshot: SE GREEN OAKS WB

The SE GREEN OAKS WB bridge in Tarrant, Texas carries SE GREEN OAKS WB over TRIBUTARY OF FISH CREEK. It was built in 1989, making it 37 years old today. The structure is built primarily of concrete and spans 3 sections, stretching 28.7 meters (94 feet) end to end. Daily traffic averages 7,244 vehicles, placing it in the moderately-trafficked tier of Texas bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. All reported major components score above the Poor range. Its NBI inventory load rating is 40.8 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How SE GREEN OAKS WB compares

▲ 12.5
Load rating vs Texas average (28.3 t)
Top 6%
Higher load rating than 94% of Texas bridges
2,617
Bridges in Tarrant · 6 in Poor condition
SE GREEN OAKS WB 40.8 t
Texas average 28.3 t

Live comparison across Texas.

Historical Sufficiency Rating

PlainBridge-computed
97.3 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
30.0
Essentiality /15
14.3
Special reductions
−2.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
40.8 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1989
Material
Concrete
Number of Spans
3
Structure Length
28.7 m (94 ft)
Deck Width
14.5 m (48 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
7,244 vehicles/day
Structure Number
022200C02423005

Condition Analysis

  • The deck (driving surface) is in good condition (7/9), showing no significant deterioration.
  • The superstructure (beams and supports above the deck) is in good condition (7/9), showing no significant deterioration.
  • At 7/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether SE GREEN OAKS WB is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare SE GREEN OAKS WB against other structures in Tarrant and across Texas. Texas bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SE GREEN OAKS WB?

SE GREEN OAKS WB in Tarrant, Texas has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is SE GREEN OAKS WB inspected?

SE GREEN OAKS WB's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 7,244 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SE GREEN OAKS WB is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SE GREEN OAKS WB?

SE GREEN OAKS WB has an NBI inventory load rating of 40.8 metric tons.

Who is responsible for maintaining SE GREEN OAKS WB?

SE GREEN OAKS WB is owned and maintained by City/Municipal Highway Agency.

How old is SE GREEN OAKS WB and does age affect safety?

SE GREEN OAKS WB was built in 1989, making it 37 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.