FHWA NBI 2024 Inspection record Public-domain dataset

FAP-367 (Army TR R

Carrying FAP-367 (Army TR R over W BR DUPAGE RIVER

1.6 MI E IL 59, DuPage, Illinois

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
21 t Inventory load rating

Bridge Snapshot: FAP-367 (Army TR R

The FAP-367 (Army TR R bridge in DuPage, Illinois carries FAP-367 (Army TR R over W BR DUPAGE RIVER. It was built in 1987, making it 39 years old today. The structure is built primarily of prestressed concrete and spans 1 section, stretching 17.8 meters (58 feet) end to end. Daily traffic averages 9,500 vehicles, placing it in the moderately-trafficked tier of Illinois bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 3/9, superstructure at 3/9, substructure at 7/9. The weakest component sits in poor condition. A component scored 4 or below, placing this bridge in the federal Poor condition category rather than declaring it unsafe or closed. Its NBI inventory load rating is 21.1 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How FAP-367 (Army TR R compares

▼ 13.5
Load rating vs Illinois average (34.6 t)
Bottom 6%
Lower load rating than 94% of Illinois bridges
380
Bridges in DuPage · 24 in Poor condition
FAP-367 (Army TR R 21.1 t
Illinois average 34.6 t

Live comparison across Illinois.

Historical Sufficiency Rating

PlainBridge-computed
35.4 / 100 - historical 20–49.9 band
Structural adequacy /55
2.6
Serviceability /30
21.0
Essentiality /15
11.8
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
3/9
Poor (1–4)
Superstructure
3/9
Poor (1–4)
Substructure
7/9
Good (7–9)
Inventory Load Rating
21.1 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1987
Material
Prestressed Concrete
Number of Spans
1
Structure Length
17.8 m (58 ft)
Deck Width
20.7 m (68 ft)
Owner
County Highway Agency
Avg Daily Traffic
9,500 vehicles/day
Structure Number
022309400000000

Condition Analysis

  • At 3/9, the deck (driving surface) is in poor shape, with advanced wear flagged for priority repair.
  • At 3/9, the superstructure (beams and supports above the deck) is in poor shape, with advanced wear flagged for priority repair.
  • The substructure (piers and abutments) rates good at 7/9, with no significant deterioration on file.

How to read this record

FAP-367 (Army TR R is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare FAP-367 (Army TR R against other structures in DuPage and across Illinois. Illinois bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for FAP-367 (Army TR R?

FAP-367 (Army TR R in DuPage, Illinois has a deck rating of 3/9, superstructure rating of 3/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is FAP-367 (Army TR R inspected?

FAP-367 (Army TR R's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 9,500 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. FAP-367 (Army TR R is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for FAP-367 (Army TR R?

FAP-367 (Army TR R has an NBI inventory load rating of 21.1 metric tons.

Who is responsible for maintaining FAP-367 (Army TR R?

FAP-367 (Army TR R is owned and maintained by County Highway Agency.

How old is FAP-367 (Army TR R and does age affect safety?

FAP-367 (Army TR R was built in 1987, making it 39 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.