FHWA NBI 2024 Inspection record Public-domain dataset

I0010

Carrying I0010 over VET MEM HWY

1.8 MI EAST OF LA 49, Jefferson, Louisiana

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
22 t Inventory load rating

Bridge Snapshot: I0010

The I0010 bridge in Jefferson, Louisiana carries I0010 over VET MEM HWY. It was built in 1967, making it 59 years old today. The structure is built primarily of prestressed concrete and spans 30 sections, stretching 798.6 meters (2620 feet) end to end. Daily traffic averages 137,542 vehicles, placing it in the heavily-trafficked tier of Louisiana bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 6/9, substructure at 4/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order. Its NBI inventory load rating is 21.7 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How I0010 compares

▼ 10.6
Load rating vs Louisiana average (32.3 t)
Bottom 22%
Lower load rating than 78% of Louisiana bridges
379
Bridges in Jefferson · 16 in Poor condition
I0010 21.7 t
Louisiana average 32.3 t

Live comparison across Louisiana.

Historical Sufficiency Rating

PlainBridge-computed
26.6 / 100 - historical 20–49.9 band
Structural adequacy /55
18.6
Serviceability /30
8.0
Essentiality /15
0.0
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
21.7 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1967
Material
Prestressed Concrete
Number of Spans
30
Structure Length
798.6 m (2620 ft)
Deck Width
14.0 m (46 ft)
Owner
State Highway Agency
Avg Daily Traffic
137,542 vehicles/day
Structure Number
022604501503821

Condition Analysis

  • At 5/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • At 6/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • The substructure (piers and abutments) rates poor at 4/9, advanced deterioration that should be prioritized for repair.

How to read this record

I0010 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare I0010 against other structures in Jefferson and across Louisiana. Louisiana bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for I0010?

I0010 in Jefferson, Louisiana has a deck rating of 5/9, superstructure rating of 6/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is I0010 inspected?

I0010's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 137,542 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. I0010 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for I0010?

I0010 has an NBI inventory load rating of 21.7 metric tons.

Who is responsible for maintaining I0010?

I0010 is owned and maintained by State Highway Agency.

How old is I0010 and does age affect safety?

I0010 was built in 1967, making it 59 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.