FHWA NBI 2024 Inspection record Public-domain dataset

US 150(FAP 91)

Carrying US 150(FAP 91) over Decatur & Eastern IL RR

2.8 MI E OF PARIS, Edgar, Illinois

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
39 t Inventory load rating

Bridge Snapshot: US 150(FAP 91)

The US 150(FAP 91) bridge in Edgar, Illinois carries US 150(FAP 91) over Decatur & Eastern IL RR. It was built in 1967, making it 59 years old today. The structure is built primarily of steel continuous and spans 3 sections, stretching 66.1 meters (217 feet) end to end. Daily traffic averages 3,250 vehicles, placing it in the moderately-trafficked tier of Illinois bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 4/9, substructure at 7/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order. Its NBI inventory load rating is 38.6 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How US 150(FAP 91) compares

▲ 4.0
Load rating vs Illinois average (34.6 t)
Top 22%
Higher load rating than 78% of Illinois bridges
278
Bridges in Edgar · 11 in Poor condition
US 150(FAP 91) 38.6 t
Illinois average 34.6 t

Live comparison across Illinois.

Historical Sufficiency Rating

PlainBridge-computed
60.6 / 100 - historical 50–79.9 band
Structural adequacy /55
30.0
Serviceability /30
19.0
Essentiality /15
11.6
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
4/9
Poor (1–4)
Substructure
7/9
Good (7–9)
Inventory Load Rating
38.6 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1967
Material
Steel Continuous
Number of Spans
3
Structure Length
66.1 m (217 ft)
Deck Width
11.0 m (36 ft)
Owner
State Highway Agency
Avg Daily Traffic
3,250 vehicles/day
Structure Number
023001400000000

Condition Analysis

  • At 5/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • At 4/9, the superstructure (beams and supports above the deck) is in poor shape, with advanced wear flagged for priority repair.
  • The substructure (piers and abutments) rates good at 7/9, with no significant deterioration on file.

How to read this record

US 150(FAP 91) is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare US 150(FAP 91) against other structures in Edgar and across Illinois. Illinois bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for US 150(FAP 91)?

US 150(FAP 91) in Edgar, Illinois has a deck rating of 5/9, superstructure rating of 4/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is US 150(FAP 91) inspected?

US 150(FAP 91)'s responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 3,250 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. US 150(FAP 91) is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for US 150(FAP 91)?

US 150(FAP 91) has an NBI inventory load rating of 38.6 metric tons.

Who is responsible for maintaining US 150(FAP 91)?

US 150(FAP 91) is owned and maintained by State Highway Agency.

How old is US 150(FAP 91) and does age affect safety?

US 150(FAP 91) was built in 1967, making it 59 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.