Fair
19 t Inventory load rating

Bridge Snapshot: PAUL VICE BRIDGE

The PAUL VICE BRIDGE bridge in Terrebonne, Louisiana carries PAUL VICE BRIDGE over DULARGE BAYOU. It was built in 1966, making it 60 years old today. The structure is built primarily of concrete and spans 2 sections, stretching 11.6 meters (38 feet) end to end. Daily traffic averages 240 vehicles, placing it in the lower-traffic tier of Louisiana bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 5/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range. Its NBI inventory load rating is 18.8 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How PAUL VICE BRIDGE compares

▼ 13.5
Load rating vs Louisiana average (32.3 t)
Bottom 14%
Lower load rating than 86% of Louisiana bridges
215
Bridges in Terrebonne · 23 in Poor condition
PAUL VICE BRIDGE 18.8 t
Louisiana average 32.3 t

Live comparison across Louisiana.

Historical Sufficiency Rating

PlainBridge-computed
67.9 / 100 - historical 50–79.9 band
Structural adequacy /55
28.7
Serviceability /30
24.3
Essentiality /15
14.9
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
18.8 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1966
Material
Concrete
Number of Spans
2
Structure Length
11.6 m (38 ft)
Deck Width
8.0 m (26 ft)
Owner
County Highway Agency
Avg Daily Traffic
240 vehicles/day
Structure Number
025529296904491

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • At 6/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • At 5/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

This page shows what the last federal inspection recorded, not whether PAUL VICE BRIDGE is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare PAUL VICE BRIDGE against other structures in Terrebonne and across Louisiana. Louisiana bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for PAUL VICE BRIDGE?

PAUL VICE BRIDGE in Terrebonne, Louisiana has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is PAUL VICE BRIDGE inspected?

PAUL VICE BRIDGE's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 240 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. PAUL VICE BRIDGE is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for PAUL VICE BRIDGE?

PAUL VICE BRIDGE has an NBI inventory load rating of 18.8 metric tons.

Who is responsible for maintaining PAUL VICE BRIDGE?

PAUL VICE BRIDGE is owned and maintained by County Highway Agency.

How old is PAUL VICE BRIDGE and does age affect safety?

PAUL VICE BRIDGE was built in 1966, making it 60 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.