FHWA NBI 2024 Inspection record Public-domain dataset

TR 60B PELLA

Carrying TR 60B PELLA over PELLA DRAINAGE DITCH

2910N,1600E, Ford, Illinois

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
28 t Inventory load rating

Bridge Snapshot: TR 60B PELLA

The TR 60B PELLA bridge in Ford, Illinois carries TR 60B PELLA over PELLA DRAINAGE DITCH. It was built in 1980, making it 46 years old today. The structure is built primarily of prestressed concrete and spans 1 section, stretching 18.3 meters (60 feet) end to end. Daily traffic averages 25 vehicles, placing it in the lower-traffic tier of Illinois bridges. It is owned and maintained by Town/Township Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 4/9, substructure at 6/9. The weakest component sits in poor condition. A component scored 4 or below, placing this bridge in the federal Poor condition category rather than declaring it unsafe or closed. Its NBI inventory load rating is 27.9 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How TR 60B PELLA compares

▼ 6.7
Load rating vs Illinois average (34.6 t)
Bottom 17%
Lower load rating than 83% of Illinois bridges
300
Bridges in Ford · 19 in Poor condition
TR 60B PELLA 27.9 t
Illinois average 34.6 t

Live comparison across Illinois.

Historical Sufficiency Rating

PlainBridge-computed
64.9 / 100 - historical 50–79.9 band
Structural adequacy /55
26.9
Serviceability /30
25.0
Essentiality /15
15.0
Special reductions
−2.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
4/9
Poor (1–4)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
27.9 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1980
Material
Prestressed Concrete
Number of Spans
1
Structure Length
18.3 m (60 ft)
Deck Width
8.3 m (27 ft)
Owner
Town/Township Highway Agency
Avg Daily Traffic
25 vehicles/day
Structure Number
027330300000000

Condition Analysis

  • At 4/9, the deck (driving surface) is in poor shape, with advanced wear flagged for priority repair.
  • The superstructure (beams and supports above the deck) rates poor at 4/9, advanced deterioration that should be prioritized for repair.
  • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

TR 60B PELLA is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare TR 60B PELLA against other structures in Ford and across Illinois. Illinois bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for TR 60B PELLA?

TR 60B PELLA in Ford, Illinois has a deck rating of 4/9, superstructure rating of 4/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is TR 60B PELLA inspected?

TR 60B PELLA's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 25 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. TR 60B PELLA is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for TR 60B PELLA?

TR 60B PELLA has an NBI inventory load rating of 27.9 metric tons.

Who is responsible for maintaining TR 60B PELLA?

TR 60B PELLA is owned and maintained by Town/Township Highway Agency.

How old is TR 60B PELLA and does age affect safety?

TR 60B PELLA was built in 1980, making it 46 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.