Good
39 t Inventory load rating

Bridge Snapshot: FAS 335, CH2

The FAS 335, CH2 bridge in Ford, Illinois carries FAS 335, CH2 over Wall Town Dr. Ditch. It was built in 2020, making it 6 years old today. The structure is built primarily of concrete continuous and spans 3 sections, stretching 22.1 meters (73 feet) end to end. Daily traffic averages 400 vehicles, placing it in the lower-traffic tier of Illinois bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 8/9, superstructure at 8/9, substructure at 8/9. The weakest component sits in good condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 38.9 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How FAS 335, CH2 compares

▲ 4.3
Load rating vs Illinois average (34.6 t)
Top 21%
Higher load rating than 79% of Illinois bridges
300
Bridges in Ford · 19 in Poor condition
FAS 335, CH2 38.9 t
Illinois average 34.6 t

Live comparison across Illinois.

Historical Sufficiency Rating

PlainBridge-computed
99.1 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
29.2
Essentiality /15
14.9
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
8/9
Good (7–9)
Superstructure
8/9
Good (7–9)
Substructure
8/9
Good (7–9)
Inventory Load Rating
38.9 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
2020
Material
Concrete Continuous
Number of Spans
3
Structure Length
22.1 m (73 ft)
Deck Width
8.5 m (28 ft)
Owner
County Highway Agency
Avg Daily Traffic
400 vehicles/day
Structure Number
027345900000000

Condition Analysis

  • At 8/9, the deck (driving surface) is in good shape and shows no significant wear.
  • The superstructure (beams and supports above the deck) rates good at 8/9, with no significant deterioration on file.
  • The substructure (piers and abutments) rates good at 8/9, with no significant deterioration on file.

How to read this record

This page shows what the last federal inspection recorded, not whether FAS 335, CH2 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare FAS 335, CH2 against other structures in Ford and across Illinois. Illinois bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for FAS 335, CH2?

FAS 335, CH2 in Ford, Illinois has a deck rating of 8/9, superstructure rating of 8/9, and substructure rating of 8/9 on the FHWA's 0–9 scale.

How often is FAS 335, CH2 inspected?

FAS 335, CH2's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 400 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. FAS 335, CH2 is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for FAS 335, CH2?

FAS 335, CH2 has an NBI inventory load rating of 38.9 metric tons.

Who is responsible for maintaining FAS 335, CH2?

FAS 335, CH2 is owned and maintained by County Highway Agency.

How old is FAS 335, CH2 and does age affect safety?

FAS 335, CH2 was built in 2020, making it 6 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.