FHWA NBI 2024 Inspection record Public-domain dataset

KY-120

Carrying KY-120 over SLOUGH OF TRADEWATER RIV

.20 MI WEST OF WEBSTER CL, Crittenden, Kentucky

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
9 t Inventory load rating

Bridge Snapshot: KY-120

The KY-120 bridge in Crittenden, Kentucky carries KY-120 over SLOUGH OF TRADEWATER RIV. It was built in 1955, making it 71 years old today. The structure is built primarily of concrete and spans 2 sections, stretching 19.5 meters (64 feet) end to end. Daily traffic averages 443 vehicles, placing it in the lower-traffic tier of Kentucky bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 4/9, substructure at 5/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 8.8 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How KY-120 compares

▼ 30.4
Load rating vs Kentucky average (39.2 t)
Bottom 2%
Lower load rating than 98% of Kentucky bridges
89
Bridges in Crittenden · 9 in Poor condition
KY-120 8.8 t
Kentucky average 39.2 t

Live comparison across Kentucky.

Historical Sufficiency Rating

PlainBridge-computed
12.4 / 100 - historical under-20 band
Structural adequacy /55
0.0
Serviceability /30
8.0
Essentiality /15
4.4
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
4/9
Poor (1–4)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
8.8 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1955
Material
Concrete
Number of Spans
2
Structure Length
19.5 m (64 ft)
Deck Width
7.3 m (24 ft)
Owner
State Highway Agency
Avg Daily Traffic
443 vehicles/day
Structure Number
028B00009N

Condition Analysis

  • At 5/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) is in poor condition (4/9), showing advanced deterioration that may require priority repair.
  • The substructure (piers and abutments) is in fair condition (5/9), with minor deterioration that may require routine maintenance.

How to read this record

KY-120 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare KY-120 against other structures in Crittenden and across Kentucky. Kentucky bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for KY-120?

KY-120 in Crittenden, Kentucky has a deck rating of 5/9, superstructure rating of 4/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is KY-120 inspected?

KY-120's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 443 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. KY-120 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for KY-120?

KY-120 has an NBI inventory load rating of 8.8 metric tons.

Who is responsible for maintaining KY-120?

KY-120 is owned and maintained by State Highway Agency.

How old is KY-120 and does age affect safety?

KY-120 was built in 1955, making it 71 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.