FHWA NBI 2024 Inspection record Public-domain dataset

FAS 452-CH 2

Carrying FAS 452-CH 2 over SPOON RIVER

AT BERNADOTTE, Fulton, Illinois

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
44 t Inventory load rating

Bridge Snapshot: FAS 452-CH 2

The FAS 452-CH 2 bridge in Fulton, Illinois carries FAS 452-CH 2 over SPOON RIVER. It was built in 1983, making it 43 years old today. The structure is built primarily of steel continuous and spans 4 sections, stretching 133.8 meters (439 feet) end to end. Daily traffic averages 375 vehicles, placing it in the lower-traffic tier of Illinois bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 4/9, substructure at 6/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 44.1 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How FAS 452-CH 2 compares

▲ 9.5
Load rating vs Illinois average (34.6 t)
Top 13%
Higher load rating than 87% of Illinois bridges
210
Bridges in Fulton · 44 in Poor condition
FAS 452-CH 2 44.1 t
Illinois average 34.6 t

Live comparison across Illinois.

Historical Sufficiency Rating

PlainBridge-computed
72.9 / 100 - historical 50–79.9 band
Structural adequacy /55
30.0
Serviceability /30
28.0
Essentiality /15
14.9
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
4/9
Poor (1–4)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
44.1 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1983
Material
Steel Continuous
Number of Spans
4
Structure Length
133.8 m (439 ft)
Deck Width
9.9 m (32 ft)
Owner
County Highway Agency
Avg Daily Traffic
375 vehicles/day
Structure Number
029321500000000

Condition Analysis

  • The deck (driving surface) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The superstructure (beams and supports above the deck) rates poor at 4/9, advanced deterioration that should be prioritized for repair.
  • At 6/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

FAS 452-CH 2 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare FAS 452-CH 2 against other structures in Fulton and across Illinois. Illinois bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for FAS 452-CH 2?

FAS 452-CH 2 in Fulton, Illinois has a deck rating of 6/9, superstructure rating of 4/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is FAS 452-CH 2 inspected?

FAS 452-CH 2's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 375 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. FAS 452-CH 2 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for FAS 452-CH 2?

FAS 452-CH 2 has an NBI inventory load rating of 44.1 metric tons.

Who is responsible for maintaining FAS 452-CH 2?

FAS 452-CH 2 is owned and maintained by County Highway Agency.

How old is FAS 452-CH 2 and does age affect safety?

FAS 452-CH 2 was built in 1983, making it 43 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.