FHWA NBI 2024 Inspection record Public-domain dataset

LA0178

Carrying LA0178 over BAYOU BOURBEAUX

0.40 MI EAST OF LA 182, St. Landry, Louisiana

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
16 t Inventory load rating

Bridge Snapshot: LA0178

The LA0178 bridge in St. Landry, Louisiana carries LA0178 over BAYOU BOURBEAUX. It was built in 1976, making it 50 years old today. The structure is built primarily of concrete and spans 6 sections, stretching 34.7 meters (114 feet) end to end. Daily traffic averages 1,619 vehicles, placing it in the moderately-trafficked tier of Louisiana bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 4/9. The weakest component sits in poor condition. A component scored 4 or below, placing this bridge in the federal Poor condition category rather than declaring it unsafe or closed. Its NBI inventory load rating is 16.2 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How LA0178 compares

▼ 16.1
Load rating vs Louisiana average (32.3 t)
Bottom 9%
Lower load rating than 91% of Louisiana bridges
317
Bridges in St. Landry · 21 in Poor condition
LA0178 16.2 t
Louisiana average 32.3 t

Live comparison across Louisiana.

Historical Sufficiency Rating

PlainBridge-computed
43.3 / 100 - historical 20–49.9 band
Structural adequacy /55
8.8
Serviceability /30
19.5
Essentiality /15
15.0
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
16.2 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1976
Material
Concrete
Number of Spans
6
Structure Length
34.7 m (114 ft)
Deck Width
9.4 m (31 ft)
Owner
State Highway Agency
Avg Daily Traffic
1,619 vehicles/day
Structure Number
034908491500411

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • At 4/9, the substructure (piers and abutments) is in poor shape, with advanced wear flagged for priority repair.

How to read this record

LA0178 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare LA0178 against other structures in St. Landry and across Louisiana. Louisiana bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for LA0178?

LA0178 in St. Landry, Louisiana has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is LA0178 inspected?

LA0178's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 1,619 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. LA0178 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for LA0178?

LA0178 has an NBI inventory load rating of 16.2 metric tons.

Who is responsible for maintaining LA0178?

LA0178 is owned and maintained by State Highway Agency.

How old is LA0178 and does age affect safety?

LA0178 was built in 1976, making it 50 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.