FHWA NBI 2024 Inspection record Public-domain dataset

I0010

Carrying I0010 over BAYOU PORTAGE

5.00 Mi W of LA 3177, St. Martin, Louisiana

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
44 t Inventory load rating

Bridge Snapshot: I0010

The I0010 bridge in St. Martin, Louisiana carries I0010 over BAYOU PORTAGE. It was built in 1970, making it 56 years old today. It was last reconstructed in 2021, extending its service life. The structure is built primarily of prestressed concrete and spans 3 sections, stretching 54.9 meters (180 feet) end to end. Daily traffic averages 1,585 vehicles, placing it in the moderately-trafficked tier of Louisiana bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range. Its NBI inventory load rating is 43.5 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How I0010 compares

▲ 11.2
Load rating vs Louisiana average (32.3 t)
Top 14%
Higher load rating than 86% of Louisiana bridges
116
Bridges in St. Martin · 10 in Poor condition
I0010 43.5 t
Louisiana average 32.3 t

Live comparison across Louisiana.

Historical Sufficiency Rating

PlainBridge-computed
93.8 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
30.0
Essentiality /15
11.8
Special reductions
−3.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
43.5 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1970
Last Reconstructed
2021
Material
Prestressed Concrete
Number of Spans
3
Structure Length
54.9 m (180 ft)
Deck Width
19.2 m (63 ft)
Owner
State Highway Agency
Avg Daily Traffic
1,585 vehicles/day
Structure Number
035004500609522

Condition Analysis

  • The deck (driving surface) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The superstructure (beams and supports above the deck) is in good condition (7/9), showing no significant deterioration.
  • The substructure (piers and abutments) rates good at 7/9, with no significant deterioration on file.

How to read this record

This page shows what the last federal inspection recorded, not whether I0010 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare I0010 against other structures in St. Martin and across Louisiana. Louisiana bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for I0010?

I0010 in St. Martin, Louisiana has a deck rating of 6/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is I0010 inspected?

I0010's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 1,585 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. I0010 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for I0010?

I0010 has an NBI inventory load rating of 43.5 metric tons.

Who is responsible for maintaining I0010?

I0010 is owned and maintained by State Highway Agency.

How old is I0010 and does age affect safety?

I0010 was built in 1970, making it 56 years old and last reconstructed in 2021.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.