FHWA NBI 2024 Inspection record Public-domain dataset

LA3147

Carrying LA3147 over HUMBLE CANAL

5.5 MI S. OF LA 82, Vermilion, Louisiana

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
9 t Inventory load rating

Bridge Snapshot: LA3147

The LA3147 bridge in Vermilion, Louisiana carries LA3147 over HUMBLE CANAL. It was built in 1982, making it 44 years old today. It was last reconstructed in 2009, extending its service life. The structure is built primarily of steel and spans 1 section, stretching 149.7 meters (491 feet) end to end. Daily traffic averages 221 vehicles, placing it in the lower-traffic tier of Louisiana bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 5/9, substructure at 4/9. The weakest component sits in poor condition. A component scored 4 or below, placing this bridge in the federal Poor condition category rather than declaring it unsafe or closed. Its NBI inventory load rating is 8.7 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How LA3147 compares

▼ 23.6
Load rating vs Louisiana average (32.3 t)
Bottom 1%
Lower load rating than 99% of Louisiana bridges
261
Bridges in Vermilion · 28 in Poor condition
LA3147 8.7 t
Louisiana average 32.3 t

Live comparison across Louisiana.

Historical Sufficiency Rating

PlainBridge-computed
35.6 / 100 - historical 20–49.9 band
Structural adequacy /55
0.0
Serviceability /30
26.0
Essentiality /15
9.6
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
8.7 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1982
Last Reconstructed
2009
Material
Steel
Number of Spans
1
Structure Length
149.7 m (491 ft)
Deck Width
9.4 m (31 ft)
Owner
State Highway Agency
Avg Daily Traffic
221 vehicles/day
Structure Number
035708576605721

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) is in poor condition (4/9), showing advanced deterioration that may require priority repair.

How to read this record

LA3147 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare LA3147 against other structures in Vermilion and across Louisiana. Louisiana bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for LA3147?

LA3147 in Vermilion, Louisiana has a deck rating of 6/9, superstructure rating of 5/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is LA3147 inspected?

LA3147's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 221 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. LA3147 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for LA3147?

LA3147 has an NBI inventory load rating of 8.7 metric tons.

Who is responsible for maintaining LA3147?

LA3147 is owned and maintained by State Highway Agency.

How old is LA3147 and does age affect safety?

LA3147 was built in 1982, making it 44 years old and last reconstructed in 2009.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.