FHWA NBI 2024 Inspection record Public-domain dataset

Treatment CS1066

Carrying Treatment CS1066 over Town Branch

242' South of 11X, Fleming, Kentucky

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
54 t Inventory load rating

Bridge Snapshot: Treatment CS1066

The Treatment CS1066 bridge in Fleming, Kentucky carries Treatment CS1066 over Town Branch. It was built in 1970, making it 56 years old today. The structure is built primarily of prestressed concrete and spans 2 sections, stretching 15.8 meters (52 feet) end to end. Daily traffic averages 80 vehicles, placing it in the lower-traffic tier of Kentucky bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 6/9. The weakest component sits in fair condition. All reported major components score above the Poor range. Its NBI inventory load rating is 54.4 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How Treatment CS1066 compares

▲ 15.2
Load rating vs Kentucky average (39.2 t)
Top 13%
Higher load rating than 87% of Kentucky bridges
117
Bridges in Fleming · 6 in Poor condition
Treatment CS1066 54.4 t
Kentucky average 39.2 t

Live comparison across Kentucky.

Historical Sufficiency Rating

PlainBridge-computed
75.1 / 100 - historical 50–79.9 band
Structural adequacy /55
55.0
Serviceability /30
14.0
Essentiality /15
14.1
Special reductions
−8.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
54.4 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1970
Material
Prestressed Concrete
Number of Spans
2
Structure Length
15.8 m (52 ft)
Deck Width
4.6 m (15 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
80 vehicles/day
Structure Number
035C00074N

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The superstructure (beams and supports above the deck) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • At 6/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

This page shows what the last federal inspection recorded, not whether Treatment CS1066 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare Treatment CS1066 against other structures in Fleming and across Kentucky. Kentucky bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for Treatment CS1066?

Treatment CS1066 in Fleming, Kentucky has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is Treatment CS1066 inspected?

Treatment CS1066's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 80 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. Treatment CS1066 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for Treatment CS1066?

Treatment CS1066 has an NBI inventory load rating of 54.4 metric tons.

Who is responsible for maintaining Treatment CS1066?

Treatment CS1066 is owned and maintained by City/Municipal Highway Agency.

How old is Treatment CS1066 and does age affect safety?

Treatment CS1066 was built in 1970, making it 56 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.