FHWA NBI 2024 Inspection record Public-domain dataset

LA0009

Carrying LA0009 over SIX MILE CREEK

1.6 MI NORTH OF LA 4, Bienville, Louisiana

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
38 t Inventory load rating

Bridge Snapshot: LA0009

The LA0009 bridge in Bienville, Louisiana carries LA0009 over SIX MILE CREEK. It was built in 1971, making it 55 years old today. The structure is built primarily of concrete and spans 6 sections, stretching 34.7 meters (114 feet) end to end. Daily traffic averages 342 vehicles, placing it in the lower-traffic tier of Louisiana bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 5/9, substructure at 4/9. The weakest component sits in poor condition. A component scored 4 or below, placing this bridge in the federal Poor condition category rather than declaring it unsafe or closed. Its NBI inventory load rating is 38.1 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How LA0009 compares

▲ 5.8
Load rating vs Louisiana average (32.3 t)
Top 29%
Higher load rating than 71% of Louisiana bridges
190
Bridges in Bienville · 49 in Poor condition
LA0009 38.1 t
Louisiana average 32.3 t

Live comparison across Louisiana.

Historical Sufficiency Rating

PlainBridge-computed
69.7 / 100 - historical 50–79.9 band
Structural adequacy /55
30.0
Serviceability /30
27.0
Essentiality /15
14.7
Special reductions
−2.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
38.1 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1971
Material
Concrete
Number of Spans
6
Structure Length
34.7 m (114 ft)
Deck Width
9.4 m (31 ft)
Owner
State Highway Agency
Avg Daily Traffic
342 vehicles/day
Structure Number
040700890311341

Condition Analysis

  • At 5/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • At 5/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • The substructure (piers and abutments) rates poor at 4/9, advanced deterioration that should be prioritized for repair.

How to read this record

LA0009 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare LA0009 against other structures in Bienville and across Louisiana. Louisiana bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for LA0009?

LA0009 in Bienville, Louisiana has a deck rating of 5/9, superstructure rating of 5/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is LA0009 inspected?

LA0009's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 342 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. LA0009 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for LA0009?

LA0009 has an NBI inventory load rating of 38.1 metric tons.

Who is responsible for maintaining LA0009?

LA0009 is owned and maintained by State Highway Agency.

How old is LA0009 and does age affect safety?

LA0009 was built in 1971, making it 55 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.