Structurally Deficient
11 t Inventory load rating

Bridge Snapshot: LA0159

The LA0159 bridge in Webster, Louisiana carries LA0159 over CYPRESS CR RELIEF. It was built in 1966, making it 60 years old today. The structure is built primarily of concrete and spans 6 sections, stretching 34.7 meters (114 feet) end to end. Daily traffic averages 866 vehicles, placing it in the lower-traffic tier of Louisiana bridges. It is owned and maintained by State Highway Agency, the entity responsible for routine inspections and any needed repairs.

The latest FHWA inspection records show a deck rating of 3/9, superstructure at 3/9, substructure at 4/9 on the 0–9 NBI scale, where 9 is excellent and 0 is failed. The weakest component sits in poor condition, which drives the overall status of this bridge. Because at least one major component scores 4 or lower, the FHWA classifies this bridge as structurally deficient — a maintenance flag, not a closure order. Its NBI inventory load rating is 11.3 metric tons — the load level the structure is rated to carry at inventory (long-term) level.

In a county that maintains hundreds of NBI-tracked bridges, LA0159 is one data point in a Louisiana inventory that FHWA inspects on a two-year cycle (more often when ratings fall). Bridge age alone is not a reliable safety signal — a 60-era structure can outperform a newer one when maintenance is consistent, materials are sound, and traffic loads stay within design limits. Use the condition ratings above, the sufficiency score, and the structurally-deficient flag together to read the bridge's real status, and check the linked county and state pages to see how this bridge ranks against its peers.

Every figure on this page comes directly from the Federal Highway Administration National Bridge Inventory (NBI), the public dataset that catalogs more than 617,000 highway bridges across the United States and is updated annually from the records that each state Department of Transportation submits to the FHWA. The condition codes use the standardized FHWA Recording and Coding Guide, the same scale that determines federal eligibility for the Highway Bridge Program and the Surface Transportation Block Grant set-aside for off-system bridges. A "structurally deficient" classification under those federal criteria is a maintenance and funding flag, never a closure order; states keep deficient bridges open with load posting, weight limits, or accelerated inspection cycles until rehabilitation or replacement is funded. See our methodology for refresh cadence and the exact NBI release vintage powering each record.

How LA0159 compares

▼ 21.0
Load rating vs Louisiana average (32.3 t)
Bottom 3%
Lower load rating than 97% of Louisiana bridges
194
Bridges in Webster · 48 structurally deficient
LA0159 11.3 t
Louisiana average 32.3 t

NBI inventory load rating (metric tons) and structural-deficiency status compared across Louisiana, computed live from the FHWA NBI.

Condition Ratings

Deck
3/9
Poor (1–4)
Superstructure
3/9
Poor (1–4)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
11.3 t
NBI inventory level (metric tons)
SD Status
Structurally Deficient

Ratings are on a 0–9 scale: 9 = Excellent, 7–8 = Good, 5–6 = Fair, 3–4 = Poor, 0–2 = Critical/Failed. Sufficiency rating (0–100) combines structural adequacy, functional obsolescence, and essentiality.

Structural Details

Year Built
1966
Material
Concrete
Number of Spans
6
Structure Length
34.7 m (114 ft)
Deck Width
8.2 m (27 ft)
Owner
State Highway Agency
Avg Daily Traffic
866 vehicles/day
Structure Number
046000870211241

Location

3.5 MI NORTH OF LA 615, Webster, Louisiana
33.015361, -93.318000
View on Google Maps ↗

Data Source

Data from the FHWA National Bridge Inventory (NBI). Bridge inspections are required every two years by federal law. Conditions reflect the most recent inspection.

FHWA NBI Program ↗

Condition Analysis

Built in 1966, this bridge is 60 years old. It carries approximately 866 vehicles per day. Based on the most recent FHWA inspection:

  • The deck (driving surface) is in poor condition (3/9), showing advanced deterioration that may require priority repair.
  • The superstructure (beams and supports above the deck) is in poor condition (3/9), showing advanced deterioration that may require priority repair.
  • The substructure (piers and abutments) is in poor condition (4/9), showing advanced deterioration that may require priority repair.

Its NBI inventory load rating is low, indicating a load-restricted structure. This bridge is classified as structurally deficient, meaning at least one major component is rated in poor condition. This does not mean the bridge is unsafe — it means it requires repair or monitoring.

Frequently Asked Questions

What do the condition ratings mean for LA0159?

Bridge condition ratings use a 0–9 scale set by the Federal Highway Administration (FHWA). Ratings 7–9 indicate good condition with no significant problems. Ratings 5–6 mean fair condition with minor issues. Ratings 3–4 indicate poor condition requiring repair. Ratings 0–2 are critical, meaning the bridge has serious structural problems. LA0159 in Webster, Louisiana has a deck rating of 3/9, superstructure rating of 3/9, and substructure rating of 4/9.

How often is LA0159 inspected?

Federal law requires most highway bridges to be inspected at least every 24 months. Bridges in poor condition or with known issues may be inspected more frequently (every 12 months or less). LA0159 is part of the National Bridge Inventory maintained by the FHWA. With 866 vehicles crossing daily, regular inspection is essential.

What does "structurally deficient" mean for a bridge?

A structurally deficient bridge has at least one major component (deck, superstructure, or substructure) rated 4 or below on the FHWA 0–9 scale. This classification does NOT mean the bridge is unsafe for travel — it means the bridge needs repair, rehabilitation, or eventual replacement. Structurally deficient bridges remain open and are monitored. LA0159 is currently classified as structurally deficient.

What is the inventory load rating for LA0159?

The NBI inventory rating is the load level a bridge is rated to carry for an indefinite period, recorded in metric tons. A lower number means the structure is more load-restricted. LA0159 has an inventory load rating of 11.3 metric tons. It is distinct from the FHWA sufficiency rating, a separate 0–100 funding-eligibility score that this dataset does not include.

Who is responsible for maintaining LA0159?

Bridge ownership and maintenance responsibility varies — bridges may be owned by state DOTs, counties, cities, railroads, or federal agencies. LA0159 is maintained by State Highway Agency. The FHWA oversees the National Bridge Inventory program and sets inspection standards, but day-to-day maintenance falls to the owning agency. If you notice damage or safety concerns, contact your state DOT or call 911 for emergencies.

How old is LA0159 and does age affect safety?

LA0159 was built in 1966, making it 60 years old. Bridge age alone does not determine safety — condition depends on materials, design, traffic load, maintenance history, and environmental exposure. Many older bridges remain in good condition due to regular maintenance and reconstruction.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A structurally deficient rating does not mean a bridge is closed or unsafe for travel — it indicates the bridge requires repair or replacement. For current closure or safety information, contact your state DOT.

Related

Data sourced from official U.S. government datasets. See our methodology for details. Retrieved and formatted by PlainBridges Editorial