FHWA NBI 2024 Inspection record Public-domain dataset

N4090

Carrying N4090 over CREEK

.3S 1W OF PIERCE, McIntosh, Oklahoma

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
13 t Inventory load rating

Bridge Snapshot: N4090

The N4090 bridge in McIntosh, Oklahoma carries N4090 over CREEK. It was built in 1941, making it 85 years old today. The structure is built primarily of concrete continuous and spans 2 sections, stretching 6.7 meters (22 feet) end to end. Daily traffic averages 100 vehicles, placing it in the lower-traffic tier of Oklahoma bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 6/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 12.9 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How N4090 compares

▼ 19.5
Load rating vs Oklahoma average (32.4 t)
Bottom 4%
Lower load rating than 96% of Oklahoma bridges
198
Bridges in McIntosh · 12 in Poor condition
N4090 12.9 t
Oklahoma average 32.4 t

Live comparison across Oklahoma.

Historical Sufficiency Rating

PlainBridge-computed
61.7 / 100 - historical 50–79.9 band
Structural adequacy /55
27.0
Serviceability /30
22.8
Essentiality /15
15.0
Special reductions
−3.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
12.9 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1941
Material
Concrete Continuous
Number of Spans
2
Structure Length
6.7 m (22 ft)
Deck Width
7.9 m (26 ft)
Owner
County Highway Agency
Avg Daily Traffic
100 vehicles/day
Structure Number
056050000000000

Condition Analysis

  • The deck (driving surface) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • At 6/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether N4090 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare N4090 against other structures in McIntosh and across Oklahoma. Oklahoma bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for N4090?

N4090 in McIntosh, Oklahoma has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is N4090 inspected?

N4090's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 100 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. N4090 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for N4090?

N4090 has an NBI inventory load rating of 12.9 metric tons.

Who is responsible for maintaining N4090?

N4090 is owned and maintained by County Highway Agency.

How old is N4090 and does age affect safety?

N4090 was built in 1941, making it 85 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.