FHWA NBI 2024 Inspection record Public-domain dataset

KY-1956

Carrying KY-1956 over ROCKCASTLE RIVER

@ ROCKCASTLE CO LINE, Laurel, Kentucky

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
38 t Inventory load rating

Bridge Snapshot: KY-1956

The KY-1956 bridge in Laurel, Kentucky carries KY-1956 over ROCKCASTLE RIVER. It was built in 1999, making it 27 years old today. The structure is built primarily of prestressed concrete continuous and spans 4 sections, stretching 111.1 meters (365 feet) end to end. Daily traffic averages 238 vehicles, placing it in the lower-traffic tier of Kentucky bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 38.0 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How KY-1956 compares

▼ 1.2
Load rating vs Kentucky average (39.2 t)
Bottom 45%
Lower load rating than 55% of Kentucky bridges
131
Bridges in Laurel · 6 in Poor condition
KY-1956 38.0 t
Kentucky average 39.2 t

Live comparison across Kentucky.

Historical Sufficiency Rating

PlainBridge-computed
94.7 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
25.0
Essentiality /15
14.8
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
38.0 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1999
Material
Prestressed Concrete Continuous
Number of Spans
4
Structure Length
111.1 m (365 ft)
Deck Width
10.0 m (33 ft)
Owner
State Highway Agency
Avg Daily Traffic
238 vehicles/day
Structure Number
063B00109N

Condition Analysis

  • The deck (driving surface) is in good condition (7/9), showing no significant deterioration.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

This page shows what the last federal inspection recorded, not whether KY-1956 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare KY-1956 against other structures in Laurel and across Kentucky. Kentucky bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for KY-1956?

KY-1956 in Laurel, Kentucky has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is KY-1956 inspected?

KY-1956's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 238 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. KY-1956 is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for KY-1956?

KY-1956 has an NBI inventory load rating of 38.0 metric tons.

Who is responsible for maintaining KY-1956?

KY-1956 is owned and maintained by State Highway Agency.

How old is KY-1956 and does age affect safety?

KY-1956 was built in 1999, making it 27 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.