Poor
8 t Inventory load rating

Bridge Snapshot: CENTRAL AVE CR 508

The CENTRAL AVE CR 508 bridge in Essex, New Jersey carries CENTRAL AVE CR 508 over CITY SUBWAY. It was built in 1908, making it 118 years old today. The structure is built primarily of steel and spans 4 sections, stretching 36.0 meters (118 feet) end to end. Daily traffic averages 11,720 vehicles, placing it in the heavily-trafficked tier of New Jersey bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 4/9, substructure at 5/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 8.2 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How CENTRAL AVE CR 508 compares

▼ 35.6
Load rating vs New Jersey average (43.8 t)
Bottom 1%
Lower load rating than 99% of New Jersey bridges
501
Bridges in Essex · 7 in Poor condition
CENTRAL AVE CR 508 8.2 t
New Jersey average 43.8 t

Live comparison across New Jersey.

Historical Sufficiency Rating

PlainBridge-computed
31.6 / 100 - historical 20–49.9 band
Structural adequacy /55
0.0
Serviceability /30
21.0
Essentiality /15
10.6
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
4/9
Poor (1–4)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
8.2 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1908
Material
Steel
Number of Spans
4
Structure Length
36.0 m (118 ft)
Deck Width
23.8 m (78 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
11,720 vehicles/day
Structure Number
0700N06

Condition Analysis

  • At 5/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) rates poor at 4/9, advanced deterioration that should be prioritized for repair.
  • The substructure (piers and abutments) is in fair condition (5/9), with minor deterioration that may require routine maintenance.

How to read this record

CENTRAL AVE CR 508 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare CENTRAL AVE CR 508 against other structures in Essex and across New Jersey. New Jersey bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for CENTRAL AVE CR 508?

CENTRAL AVE CR 508 in Essex, New Jersey has a deck rating of 5/9, superstructure rating of 4/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is CENTRAL AVE CR 508 inspected?

CENTRAL AVE CR 508's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 11,720 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. CENTRAL AVE CR 508 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for CENTRAL AVE CR 508?

CENTRAL AVE CR 508 has an NBI inventory load rating of 8.2 metric tons.

Who is responsible for maintaining CENTRAL AVE CR 508?

CENTRAL AVE CR 508 is owned and maintained by City/Municipal Highway Agency.

How old is CENTRAL AVE CR 508 and does age affect safety?

CENTRAL AVE CR 508 was built in 1908, making it 118 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.