FHWA NBI 2024 Inspection record Public-domain dataset

KY-819

Carrying KY-819 over PANTHER CREEK

1.8 MI NOR. OF JCT KY 93W, Lyon, Kentucky

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
7 t Inventory load rating

Bridge Snapshot: KY-819

The KY-819 bridge in Lyon, Kentucky carries KY-819 over PANTHER CREEK. It was built in 1974, making it 52 years old today. The structure is built primarily of prestressed concrete and spans 1 section, stretching 12.8 meters (42 feet) end to end. Daily traffic averages 136 vehicles, placing it in the lower-traffic tier of Kentucky bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 4/9, substructure at 6/9. The weakest component sits in poor condition. A component scored 4 or below, placing this bridge in the federal Poor condition category rather than declaring it unsafe or closed. Its NBI inventory load rating is 7.0 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How KY-819 compares

▼ 32.2
Load rating vs Kentucky average (39.2 t)
Bottom 2%
Lower load rating than 98% of Kentucky bridges
78
Bridges in Lyon · 3 in Poor condition
KY-819 7.0 t
Kentucky average 39.2 t

Live comparison across Kentucky.

Historical Sufficiency Rating

PlainBridge-computed
27.8 / 100 - historical 20–49.9 band
Structural adequacy /55
0.0
Serviceability /30
12.8
Essentiality /15
15.0
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
4/9
Poor (1–4)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
7.0 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1974
Material
Prestressed Concrete
Number of Spans
1
Structure Length
12.8 m (42 ft)
Deck Width
7.3 m (24 ft)
Owner
State Highway Agency
Avg Daily Traffic
136 vehicles/day
Structure Number
072B00031N

Condition Analysis

  • The deck (driving surface) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • The superstructure (beams and supports above the deck) rates poor at 4/9, advanced deterioration that should be prioritized for repair.
  • At 6/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

KY-819 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare KY-819 against other structures in Lyon and across Kentucky. Kentucky bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for KY-819?

KY-819 in Lyon, Kentucky has a deck rating of 5/9, superstructure rating of 4/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is KY-819 inspected?

KY-819's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 136 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. KY-819 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for KY-819?

KY-819 has an NBI inventory load rating of 7.0 metric tons.

Who is responsible for maintaining KY-819?

KY-819 is owned and maintained by State Highway Agency.

How old is KY-819 and does age affect safety?

KY-819 was built in 1974, making it 52 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.