FHWA NBI 2024 Inspection record Public-domain dataset

NFSR 1178

Carrying NFSR 1178 over CHATTOOGA RIVER (COMPLEX

NATIONAL FOREST, Macon, North Carolina

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
14 t Inventory load rating

Bridge Snapshot: NFSR 1178

The NFSR 1178 bridge in Macon, North Carolina carries NFSR 1178 over CHATTOOGA RIVER (COMPLEX. It was built in 1934, making it 92 years old today. The structure is built primarily of steel and spans 1 section, stretching 25.1 meters (82 feet) end to end. Daily traffic averages 50 vehicles, placing it in the lower-traffic tier of North Carolina bridges. It is owned and maintained by U.S. Forest Service.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 4/9, substructure at 6/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order. Its NBI inventory load rating is 13.9 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How NFSR 1178 compares

▼ 30.3
Load rating vs North Carolina average (44.2 t)
Bottom 3%
Lower load rating than 97% of North Carolina bridges
223
Bridges in Macon · 39 in Poor condition
NFSR 1178 13.9 t
North Carolina average 44.2 t

Live comparison across North Carolina.

Historical Sufficiency Rating

PlainBridge-computed
9.1 / 100 - historical under-20 band
Structural adequacy /55
4.1
Serviceability /30
5.0
Essentiality /15
0.0
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
4/9
Poor (1–4)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
13.9 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1934
Material
Steel
Number of Spans
1
Structure Length
25.1 m (82 ft)
Deck Width
3.7 m (12 ft)
Owner
U.S. Forest Service
Avg Daily Traffic
50 vehicles/day
Structure Number
081106000003086

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The superstructure (beams and supports above the deck) rates poor at 4/9, advanced deterioration that should be prioritized for repair.
  • At 6/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

NFSR 1178 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare NFSR 1178 against other structures in Macon and across North Carolina. North Carolina bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for NFSR 1178?

NFSR 1178 in Macon, North Carolina has a deck rating of 6/9, superstructure rating of 4/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is NFSR 1178 inspected?

NFSR 1178's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 50 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. NFSR 1178 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for NFSR 1178?

NFSR 1178 has an NBI inventory load rating of 13.9 metric tons.

Who is responsible for maintaining NFSR 1178?

NFSR 1178 is owned and maintained by U.S. Forest Service.

How old is NFSR 1178 and does age affect safety?

NFSR 1178 was built in 1934, making it 92 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.