FHWA NBI record, refreshed with each annual release.

Poor
23 t Inventory load rating

Bridge Snapshot: ELECTRIC AVENUE

The ELECTRIC AVENUE bridge in Whatcom, Washington carries ELECTRIC AVENUE over WHATCOM CREEK. It was built in 1959, making it 67 years old today. The structure is built primarily of concrete and spans 3 sections, stretching 17.4 meters (57 feet) end to end. Daily traffic averages 8,500 vehicles, placing it in the moderately-trafficked tier of Washington bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 5/9, substructure at 4/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 22.7 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How ELECTRIC AVENUE compares

▼ 10.8
Load rating vs Washington average (33.5 t)
Bottom 25%
Lower load rating than 75% of Washington bridges
358
Bridges in Whatcom · 19 in Poor condition
ELECTRIC AVENUE 22.7 t
Washington average 33.5 t

Live comparison across Washington.

Historical Sufficiency Rating

PlainBridge-computed
37.2 / 100 - historical 20–49.9 band
Structural adequacy /55
20.2
Serviceability /30
9.0
Essentiality /15
8.0
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
22.7 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1959
Material
Concrete
Number of Spans
3
Structure Length
17.4 m (57 ft)
Deck Width
9.1 m (30 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
8,500 vehicles/day
Structure Number
085375000000000

Condition Analysis

  • At 6/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • The superstructure (beams and supports above the deck) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) is in poor condition (4/9), showing advanced deterioration that may require priority repair.

How to read this record

ELECTRIC AVENUE is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare ELECTRIC AVENUE against other structures in Whatcom and across Washington. Washington bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for ELECTRIC AVENUE?

ELECTRIC AVENUE in Whatcom, Washington has a deck rating of 6/9, superstructure rating of 5/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is ELECTRIC AVENUE inspected?

ELECTRIC AVENUE's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 8,500 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. ELECTRIC AVENUE is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for ELECTRIC AVENUE?

ELECTRIC AVENUE has an NBI inventory load rating of 22.7 metric tons.

Who is responsible for maintaining ELECTRIC AVENUE?

ELECTRIC AVENUE is owned and maintained by City/Municipal Highway Agency.

How old is ELECTRIC AVENUE and does age affect safety?

ELECTRIC AVENUE was built in 1959, making it 67 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.