FHWA NBI 2024 Inspection record Public-domain dataset

SR 397

Carrying SR 397 over BNSF RR

16.5 N JCT I-82, Benton, Washington

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
44 t Inventory load rating

Bridge Snapshot: SR 397

The SR 397 bridge in Benton, Washington carries SR 397 over BNSF RR. It was built in 1965, making it 61 years old today. It was last reconstructed in 1995, extending its service life. The structure is built primarily of prestressed concrete and spans 3 sections, stretching 80.3 meters (263 feet) end to end. Daily traffic averages 11,543 vehicles, placing it in the heavily-trafficked tier of Washington bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 6/9, substructure at 6/9. The weakest component sits in fair condition. All reported major components score above the Poor range. Its NBI inventory load rating is 44.4 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How SR 397 compares

▲ 10.9
Load rating vs Washington average (33.5 t)
Top 18%
Higher load rating than 82% of Washington bridges
173
Bridges in Benton · 8 in Poor condition
SR 397 44.4 t
Washington average 33.5 t

Live comparison across Washington.

Historical Sufficiency Rating

PlainBridge-computed
89.0 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
22.0
Essentiality /15
12.0
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
6/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
44.4 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1965
Last Reconstructed
1995
Material
Prestressed Concrete
Number of Spans
3
Structure Length
80.3 m (263 ft)
Deck Width
10.6 m (35 ft)
Owner
State Highway Agency
Avg Daily Traffic
11,543 vehicles/day
Structure Number
085664000000000

Condition Analysis

  • The deck (driving surface) is in good condition (7/9), showing no significant deterioration.
  • The superstructure (beams and supports above the deck) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether SR 397 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare SR 397 against other structures in Benton and across Washington. Washington bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SR 397?

SR 397 in Benton, Washington has a deck rating of 7/9, superstructure rating of 6/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is SR 397 inspected?

SR 397's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 11,543 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SR 397 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SR 397?

SR 397 has an NBI inventory load rating of 44.4 metric tons.

Who is responsible for maintaining SR 397?

SR 397 is owned and maintained by State Highway Agency.

How old is SR 397 and does age affect safety?

SR 397 was built in 1965, making it 61 years old and last reconstructed in 1995.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.