FHWA NBI 2024 Inspection record Public-domain dataset

Everett Avenue

Carrying Everett Avenue over BNSF RR

Inter Terminal & Everett, Snohomish, Washington

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
52 t Inventory load rating

Bridge Snapshot: Everett Avenue

The Everett Avenue bridge in Snohomish, Washington carries Everett Avenue over BNSF RR. It was built in 2003, making it 23 years old today. The structure is built primarily of prestressed concrete and spans 2 sections, stretching 56.7 meters (186 feet) end to end. Daily traffic averages 967 vehicles, placing it in the lower-traffic tier of Washington bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. All reported major components score above the Poor range. Its NBI inventory load rating is 51.7 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How Everett Avenue compares

▲ 18.2
Load rating vs Washington average (33.5 t)
Top 11%
Higher load rating than 89% of Washington bridges
516
Bridges in Snohomish · 19 in Poor condition
Everett Avenue 51.7 t
Washington average 33.5 t

Live comparison across Washington.

Historical Sufficiency Rating

PlainBridge-computed
85.0 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
27.4
Essentiality /15
7.6
Special reductions
−5.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
51.7 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
2003
Material
Prestressed Concrete
Number of Spans
2
Structure Length
56.7 m (186 ft)
Deck Width
16.9 m (55 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
967 vehicles/day
Structure Number
087271000000000

Condition Analysis

  • At 7/9, the deck (driving surface) is in good shape and shows no significant wear.
  • The superstructure (beams and supports above the deck) is in good condition (7/9), showing no significant deterioration.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

This page shows what the last federal inspection recorded, not whether Everett Avenue is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare Everett Avenue against other structures in Snohomish and across Washington. Washington bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for Everett Avenue?

Everett Avenue in Snohomish, Washington has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is Everett Avenue inspected?

Everett Avenue's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 967 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. Everett Avenue is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for Everett Avenue?

Everett Avenue has an NBI inventory load rating of 51.7 metric tons.

Who is responsible for maintaining Everett Avenue?

Everett Avenue is owned and maintained by City/Municipal Highway Agency.

How old is Everett Avenue and does age affect safety?

Everett Avenue was built in 2003, making it 23 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.