Fair
46 t Inventory load rating

Bridge Snapshot: US20 FREPORT BYPS

The US20 FREPORT BYPS bridge in Stephenson, Illinois carries US20 FREPORT BYPS over PECATONICA RIVER. It was built in 1987, making it 39 years old today. The structure is built primarily of steel and spans 7 sections, stretching 231.0 meters (758 feet) end to end. Daily traffic averages 6,150 vehicles, placing it in the moderately-trafficked tier of Illinois bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 5/9, substructure at 6/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range. Its NBI inventory load rating is 46.3 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How US20 FREPORT BYPS compares

▲ 11.7
Load rating vs Illinois average (34.6 t)
Top 10%
Higher load rating than 90% of Illinois bridges
332
Bridges in Stephenson · 9 in Poor condition
US20 FREPORT BYPS 46.3 t
Illinois average 34.6 t

Live comparison across Illinois.

Historical Sufficiency Rating

PlainBridge-computed
82.6 / 100 - historical 80–100 band
Structural adequacy /55
45.0
Serviceability /30
28.0
Essentiality /15
9.6
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
46.3 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1987
Material
Steel
Number of Spans
7
Structure Length
231.0 m (758 ft)
Deck Width
14.4 m (47 ft)
Owner
State Highway Agency
Avg Daily Traffic
6,150 vehicles/day
Structure Number
089004500000000

Condition Analysis

  • The deck (driving surface) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • At 5/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether US20 FREPORT BYPS is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare US20 FREPORT BYPS against other structures in Stephenson and across Illinois. Illinois bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for US20 FREPORT BYPS?

US20 FREPORT BYPS in Stephenson, Illinois has a deck rating of 5/9, superstructure rating of 5/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is US20 FREPORT BYPS inspected?

US20 FREPORT BYPS's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 6,150 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. US20 FREPORT BYPS is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for US20 FREPORT BYPS?

US20 FREPORT BYPS has an NBI inventory load rating of 46.3 metric tons.

Who is responsible for maintaining US20 FREPORT BYPS?

US20 FREPORT BYPS is owned and maintained by State Highway Agency.

How old is US20 FREPORT BYPS and does age affect safety?

US20 FREPORT BYPS was built in 1987, making it 39 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.