FHWA NBI 2024 Inspection record Public-domain dataset

MANHATTAN AVECR683

Carrying MANHATTAN AVECR683 over GORGE

0.04 MI. N OF 14TH ST, Hudson, New Jersey

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
38 t Inventory load rating

Bridge Snapshot: MANHATTAN AVECR683

The MANHATTAN AVECR683 bridge in Hudson, New Jersey carries MANHATTAN AVECR683 over GORGE. It was built in 1939, making it 87 years old today. It was last reconstructed in 1993, extending its service life. The structure is built primarily of steel and spans 12 sections, stretching 212.8 meters (698 feet) end to end. Daily traffic averages 6,055 vehicles, placing it in the moderately-trafficked tier of New Jersey bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 6/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range. Its NBI inventory load rating is 38.1 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How MANHATTAN AVECR683 compares

▼ 5.7
Load rating vs New Jersey average (43.8 t)
Bottom 49%
Lower load rating than 51% of New Jersey bridges
202
Bridges in Hudson · 6 in Poor condition
MANHATTAN AVECR683 38.1 t
New Jersey average 43.8 t

Live comparison across New Jersey.

Historical Sufficiency Rating

PlainBridge-computed
94.1 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
28.0
Essentiality /15
14.1
Special reductions
−3.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
38.1 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1939
Last Reconstructed
1993
Material
Steel
Number of Spans
12
Structure Length
212.8 m (698 ft)
Deck Width
14.2 m (47 ft)
Owner
County Highway Agency
Avg Daily Traffic
6,055 vehicles/day
Structure Number
0900017

Condition Analysis

  • At 7/9, the deck (driving surface) is in good shape and shows no significant wear.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • At 6/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

This page shows what the last federal inspection recorded, not whether MANHATTAN AVECR683 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare MANHATTAN AVECR683 against other structures in Hudson and across New Jersey. New Jersey bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for MANHATTAN AVECR683?

MANHATTAN AVECR683 in Hudson, New Jersey has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is MANHATTAN AVECR683 inspected?

MANHATTAN AVECR683's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 6,055 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. MANHATTAN AVECR683 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for MANHATTAN AVECR683?

MANHATTAN AVECR683 has an NBI inventory load rating of 38.1 metric tons.

Who is responsible for maintaining MANHATTAN AVECR683?

MANHATTAN AVECR683 is owned and maintained by County Highway Agency.

How old is MANHATTAN AVECR683 and does age affect safety?

MANHATTAN AVECR683 was built in 1939, making it 87 years old and last reconstructed in 1993.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.