FHWA NBI 2024 Inspection record Public-domain dataset

THIRD ST

Carrying THIRD ST over RR, CITY PARK

NW-10-T22NR4W, Tazewell, Illinois

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
32 t Inventory load rating

Bridge Snapshot: THIRD ST

The THIRD ST bridge in Tazewell, Illinois carries THIRD ST over RR, CITY PARK. It was built in 1900, making it 126 years old today. It was last reconstructed in 2003, extending its service life. The structure is built primarily of steel and spans 1 section, stretching 25.2 meters (83 feet) end to end. Daily traffic averages 60 vehicles, placing it in the lower-traffic tier of Illinois bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 7/9, substructure at 6/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 32.4 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How THIRD ST compares

▼ 2.2
Load rating vs Illinois average (34.6 t)
Bottom 23%
Lower load rating than 77% of Illinois bridges
361
Bridges in Tazewell · 40 in Poor condition
THIRD ST 32.4 t
Illinois average 34.6 t

Live comparison across Illinois.

Historical Sufficiency Rating

PlainBridge-computed
75.7 / 100 - historical 50–79.9 band
Structural adequacy /55
55.0
Serviceability /30
10.8
Essentiality /15
14.9
Special reductions
−5.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
7/9
Good (7–9)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
32.4 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1900
Last Reconstructed
2003
Material
Steel
Number of Spans
1
Structure Length
25.2 m (83 ft)
Deck Width
7.0 m (23 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
60 vehicles/day
Structure Number
090991200000000

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether THIRD ST is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare THIRD ST against other structures in Tazewell and across Illinois. Illinois bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for THIRD ST?

THIRD ST in Tazewell, Illinois has a deck rating of 6/9, superstructure rating of 7/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is THIRD ST inspected?

THIRD ST's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 60 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. THIRD ST is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for THIRD ST?

THIRD ST has an NBI inventory load rating of 32.4 metric tons.

Who is responsible for maintaining THIRD ST?

THIRD ST is owned and maintained by City/Municipal Highway Agency.

How old is THIRD ST and does age affect safety?

THIRD ST was built in 1900, making it 126 years old and last reconstructed in 2003.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.