FHWA NBI 2024 Inspection record Public-domain dataset

FDR 29

Carrying FDR 29 over WALKER BROOK

MAP 29, Grafton, New Hampshire

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
21 t Inventory load rating

Bridge Snapshot: FDR 29

The FDR 29 bridge in Grafton, New Hampshire carries FDR 29 over WALKER BROOK. It was built in 1975, making it 51 years old today. The structure is built primarily of wood or timber and spans 1 section, stretching 9.8 meters (32 feet) end to end. Daily traffic averages 50 vehicles, placing it in the lower-traffic tier of New Hampshire bridges. It is owned and maintained by U.S. Forest Service.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 6/9, substructure at 7/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 21.1 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How FDR 29 compares

▼ 17.1
Load rating vs New Hampshire average (38.2 t)
Bottom 15%
Lower load rating than 85% of New Hampshire bridges
544
Bridges in Grafton · 43 in Poor condition
FDR 29 21.1 t
New Hampshire average 38.2 t

Live comparison across New Hampshire.

Historical Sufficiency Rating

PlainBridge-computed
61.1 / 100 - historical 50–79.9 band
Structural adequacy /55
42.6
Serviceability /30
12.0
Essentiality /15
14.4
Special reductions
−7.9

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
6/9
Fair (5–6)
Substructure
7/9
Good (7–9)
Inventory Load Rating
21.1 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1975
Material
Wood or Timber
Number of Spans
1
Structure Length
9.8 m (32 ft)
Deck Width
5.0 m (16 ft)
Owner
U.S. Forest Service
Avg Daily Traffic
50 vehicles/day
Structure Number
092204000001050

Condition Analysis

  • The deck (driving surface) rates poor at 4/9, advanced deterioration that should be prioritized for repair.
  • The superstructure (beams and supports above the deck) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) is in good condition (7/9), showing no significant deterioration.

How to read this record

FDR 29 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare FDR 29 against other structures in Grafton and across New Hampshire. New Hampshire bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for FDR 29?

FDR 29 in Grafton, New Hampshire has a deck rating of 4/9, superstructure rating of 6/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is FDR 29 inspected?

FDR 29's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 50 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. FDR 29 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for FDR 29?

FDR 29 has an NBI inventory load rating of 21.1 metric tons.

Who is responsible for maintaining FDR 29?

FDR 29 is owned and maintained by U.S. Forest Service.

How old is FDR 29 and does age affect safety?

FDR 29 was built in 1975, making it 51 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.