FHWA NBI 2024 Inspection record Public-domain dataset

ILL 172

Carrying ILL 172 over HENNEPIN CANAL FEEDR

3.2 MI W JCT ILL 40, Whiteside, Illinois

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
42 t Inventory load rating

Bridge Snapshot: ILL 172

The ILL 172 bridge in Whiteside, Illinois carries ILL 172 over HENNEPIN CANAL FEEDR. It was built in 1972, making it 54 years old today. It was last reconstructed in 2001, extending its service life. The structure is built primarily of prestressed concrete and spans 3 sections, stretching 36.2 meters (119 feet) end to end. Daily traffic averages 800 vehicles, placing it in the lower-traffic tier of Illinois bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 7/9, substructure at 6/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range. Its NBI inventory load rating is 42.1 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How ILL 172 compares

▲ 7.5
Load rating vs Illinois average (34.6 t)
Top 15%
Higher load rating than 85% of Illinois bridges
280
Bridges in Whiteside · 23 in Poor condition
ILL 172 42.1 t
Illinois average 34.6 t

Live comparison across Illinois.

Historical Sufficiency Rating

PlainBridge-computed
99.0 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
30.0
Essentiality /15
14.0
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
7/9
Good (7–9)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
42.1 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1972
Last Reconstructed
2001
Material
Prestressed Concrete
Number of Spans
3
Structure Length
36.2 m (119 ft)
Deck Width
11.0 m (36 ft)
Owner
State Highway Agency
Avg Daily Traffic
800 vehicles/day
Structure Number
098005400000000

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The superstructure (beams and supports above the deck) rates good at 7/9, with no significant deterioration on file.
  • The substructure (piers and abutments) rates fair at 6/9, minor deterioration that routine maintenance should address.

How to read this record

This page shows what the last federal inspection recorded, not whether ILL 172 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare ILL 172 against other structures in Whiteside and across Illinois. Illinois bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for ILL 172?

ILL 172 in Whiteside, Illinois has a deck rating of 6/9, superstructure rating of 7/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is ILL 172 inspected?

ILL 172's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 800 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. ILL 172 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for ILL 172?

ILL 172 has an NBI inventory load rating of 42.1 metric tons.

Who is responsible for maintaining ILL 172?

ILL 172 is owned and maintained by State Highway Agency.

How old is ILL 172 and does age affect safety?

ILL 172 was built in 1972, making it 54 years old and last reconstructed in 2001.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.