FHWA NBI 2024 Inspection record Public-domain dataset

GENESEE COURT

Carrying GENESEE COURT over ROCK CREEK

SO EDGE OF MORRISON, Whiteside, Illinois

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
25 t Inventory load rating

Bridge Snapshot: GENESEE COURT

The GENESEE COURT bridge in Whiteside, Illinois carries GENESEE COURT over ROCK CREEK. It was built in 1981, making it 45 years old today. The structure is built primarily of prestressed concrete and spans 3 sections, stretching 40.4 meters (133 feet) end to end. Daily traffic averages 1,100 vehicles, placing it in the moderately-trafficked tier of Illinois bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 3/9, superstructure at 3/9, substructure at 5/9. The weakest component sits in poor condition. A component scored 4 or below, placing this bridge in the federal Poor condition category rather than declaring it unsafe or closed. Its NBI inventory load rating is 24.6 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How GENESEE COURT compares

▼ 10.0
Load rating vs Illinois average (34.6 t)
Bottom 13%
Lower load rating than 87% of Illinois bridges
280
Bridges in Whiteside · 23 in Poor condition
GENESEE COURT 24.6 t
Illinois average 34.6 t

Live comparison across Illinois.

Historical Sufficiency Rating

PlainBridge-computed
43.0 / 100 - historical 20–49.9 band
Structural adequacy /55
7.9
Serviceability /30
21.0
Essentiality /15
14.1
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
3/9
Poor (1–4)
Superstructure
3/9
Poor (1–4)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
24.6 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1981
Material
Prestressed Concrete
Number of Spans
3
Structure Length
40.4 m (133 ft)
Deck Width
11.0 m (36 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
1,100 vehicles/day
Structure Number
098505700000000

Condition Analysis

  • The deck (driving surface) rates poor at 3/9, advanced deterioration that should be prioritized for repair.
  • The superstructure (beams and supports above the deck) rates poor at 3/9, advanced deterioration that should be prioritized for repair.
  • At 5/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

GENESEE COURT is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare GENESEE COURT against other structures in Whiteside and across Illinois. Illinois bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for GENESEE COURT?

GENESEE COURT in Whiteside, Illinois has a deck rating of 3/9, superstructure rating of 3/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is GENESEE COURT inspected?

GENESEE COURT's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 1,100 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. GENESEE COURT is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for GENESEE COURT?

GENESEE COURT has an NBI inventory load rating of 24.6 metric tons.

Who is responsible for maintaining GENESEE COURT?

GENESEE COURT is owned and maintained by City/Municipal Highway Agency.

How old is GENESEE COURT and does age affect safety?

GENESEE COURT was built in 1981, making it 45 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.