FHWA NBI 2024 Inspection record Public-domain dataset

PARK STREET

Carrying PARK STREET over CLATSKANIE RIVER

CLATSKANIE N CITY LIMITS, Columbia, Oregon

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
21 t Inventory load rating

Bridge Snapshot: PARK STREET

The PARK STREET bridge in Columbia, Oregon carries PARK STREET over CLATSKANIE RIVER. It was built in 1986, making it 40 years old today. The structure is built primarily of prestressed concrete and spans 1 section, stretching 34.7 meters (114 feet) end to end. Daily traffic averages 277 vehicles, placing it in the lower-traffic tier of Oregon bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 4/9. The weakest component sits in poor condition. A component scored 4 or below, placing this bridge in the federal Poor condition category rather than declaring it unsafe or closed. Its NBI inventory load rating is 20.7 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How PARK STREET compares

▼ 11.6
Load rating vs Oregon average (32.3 t)
Bottom 22%
Lower load rating than 78% of Oregon bridges
126
Bridges in Columbia · 10 in Poor condition
PARK STREET 20.7 t
Oregon average 32.3 t

Live comparison across Oregon.

Historical Sufficiency Rating

PlainBridge-computed
48.1 / 100 - historical 20–49.9 band
Structural adequacy /55
17.0
Serviceability /30
16.2
Essentiality /15
15.0
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
20.7 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1986
Material
Prestressed Concrete
Number of Spans
1
Structure Length
34.7 m (114 ft)
Deck Width
11.0 m (36 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
277 vehicles/day
Structure Number
09B02 000 00010

Condition Analysis

  • The deck (driving surface) rates good at 7/9, with no significant deterioration on file.
  • The superstructure (beams and supports above the deck) is in good condition (7/9), showing no significant deterioration.
  • The substructure (piers and abutments) is in poor condition (4/9), showing advanced deterioration that may require priority repair.

How to read this record

PARK STREET is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare PARK STREET against other structures in Columbia and across Oregon. Oregon bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for PARK STREET?

PARK STREET in Columbia, Oregon has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is PARK STREET inspected?

PARK STREET's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 277 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. PARK STREET is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for PARK STREET?

PARK STREET has an NBI inventory load rating of 20.7 metric tons.

Who is responsible for maintaining PARK STREET?

PARK STREET is owned and maintained by City/Municipal Highway Agency.

How old is PARK STREET and does age affect safety?

PARK STREET was built in 1986, making it 40 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.