FHWA NBI 2024 Inspection record Public-domain dataset

C2002

Carrying C2002 over OTTER CREEK

0.08 MI TO JCT W CL3 TH9, Addison, Vermont

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
34 t Inventory load rating

Bridge Snapshot: C2002

The C2002 bridge in Addison, Vermont carries C2002 over OTTER CREEK. It was built in 1970, making it 56 years old today. The structure is built primarily of steel continuous and spans 3 sections, stretching 49.4 meters (162 feet) end to end. Daily traffic averages 500 vehicles, placing it in the lower-traffic tier of Vermont bridges. It is owned and maintained by Town/Township Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 8/9, substructure at 6/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range. Its NBI inventory load rating is 33.6 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How C2002 compares

▼ 3.1
Load rating vs Vermont average (36.7 t)
Bottom 45%
Lower load rating than 55% of Vermont bridges
146
Bridges in Addison · 4 in Poor condition
C2002 33.6 t
Vermont average 36.7 t

Live comparison across Vermont.

Historical Sufficiency Rating

PlainBridge-computed
80.7 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
11.0
Essentiality /15
14.7
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
8/9
Good (7–9)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
33.6 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1970
Material
Steel Continuous
Number of Spans
3
Structure Length
49.4 m (162 ft)
Deck Width
8.9 m (29 ft)
Owner
Town/Township Highway Agency
Avg Daily Traffic
500 vehicles/day
Structure Number
100122000701221

Condition Analysis

  • The deck (driving surface) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • At 8/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • At 6/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

This page shows what the last federal inspection recorded, not whether C2002 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare C2002 against other structures in Addison and across Vermont. Vermont bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for C2002?

C2002 in Addison, Vermont has a deck rating of 6/9, superstructure rating of 8/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is C2002 inspected?

C2002's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 500 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. C2002 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for C2002?

C2002 has an NBI inventory load rating of 33.6 metric tons.

Who is responsible for maintaining C2002?

C2002 is owned and maintained by Town/Township Highway Agency.

How old is C2002 and does age affect safety?

C2002 was built in 1970, making it 56 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.