FHWA NBI 2024 Inspection record Public-domain dataset

C3060

Carrying C3060 over 1ST BRANCH WHITE R.

AT JCT TH 60 + VT 110, Orange, Vermont

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
7 t Inventory load rating

Bridge Snapshot: C3060

The C3060 bridge in Orange, Vermont carries C3060 over 1ST BRANCH WHITE R.. It was built in 1879, making it 147 years old today. It was last reconstructed in 1995, extending its service life. The structure is built primarily of wood or timber and spans 1 section, stretching 22.6 meters (74 feet) end to end. Daily traffic averages 50 vehicles, placing it in the lower-traffic tier of Vermont bridges. It is owned and maintained by Town/Township Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 6/9, substructure at 6/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range. Its NBI inventory load rating is 7.3 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How C3060 compares

▼ 29.4
Load rating vs Vermont average (36.7 t)
Bottom 2%
Lower load rating than 98% of Vermont bridges
210
Bridges in Orange · 4 in Poor condition
C3060 7.3 t
Vermont average 36.7 t

Live comparison across Vermont.

Historical Sufficiency Rating

PlainBridge-computed
32.0 / 100 - historical 20–49.9 band
Structural adequacy /55
14.1
Serviceability /30
3.0
Essentiality /15
14.9
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
6/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
7.3 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1879
Last Reconstructed
1995
Material
Wood or Timber
Number of Spans
1
Structure Length
22.6 m (74 ft)
Deck Width
4.1 m (13 ft)
Owner
Town/Township Highway Agency
Avg Daily Traffic
50 vehicles/day
Structure Number
100913003209131

Condition Analysis

  • At 7/9, the deck (driving surface) is in good shape and shows no significant wear.
  • The superstructure (beams and supports above the deck) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) rates fair at 6/9, minor deterioration that routine maintenance should address.

How to read this record

This page shows what the last federal inspection recorded, not whether C3060 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare C3060 against other structures in Orange and across Vermont. Vermont bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for C3060?

C3060 in Orange, Vermont has a deck rating of 7/9, superstructure rating of 6/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is C3060 inspected?

C3060's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 50 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. C3060 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for C3060?

C3060 has an NBI inventory load rating of 7.3 metric tons.

Who is responsible for maintaining C3060?

C3060 is owned and maintained by Town/Township Highway Agency.

How old is C3060 and does age affect safety?

C3060 was built in 1879, making it 147 years old and last reconstructed in 1995.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.