FHWA NBI 2024 Inspection record Public-domain dataset

C3057

Carrying C3057 over N.E.C.R.R. & DOG RIVER

0.1 MI TO JCT W VT12A, Washington, Vermont

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
13 t Inventory load rating

Bridge Snapshot: C3057

The C3057 bridge in Washington, Vermont carries C3057 over N.E.C.R.R. & DOG RIVER. It was built in 1908, making it 118 years old today. It was last reconstructed in 1986, extending its service life. The structure is built primarily of steel and spans 1 section, stretching 27.7 meters (91 feet) end to end. Daily traffic averages 150 vehicles, placing it in the lower-traffic tier of Vermont bridges. It is owned and maintained by Railroad.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 4/9, substructure at 5/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 12.7 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How C3057 compares

▼ 24.0
Load rating vs Vermont average (36.7 t)
Bottom 6%
Lower load rating than 94% of Vermont bridges
254
Bridges in Washington · 9 in Poor condition
C3057 12.7 t
Vermont average 36.7 t

Live comparison across Vermont.

Historical Sufficiency Rating

PlainBridge-computed
21.9 / 100 - historical 20–49.9 band
Structural adequacy /55
1.5
Serviceability /30
6.0
Essentiality /15
14.4
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
4/9
Poor (1–4)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
12.7 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1908
Last Reconstructed
1986
Material
Steel
Number of Spans
1
Structure Length
27.7 m (91 ft)
Deck Width
4.9 m (16 ft)
Owner
Railroad
Avg Daily Traffic
150 vehicles/day
Structure Number
101213006512131

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The superstructure (beams and supports above the deck) rates poor at 4/9, advanced deterioration that should be prioritized for repair.
  • The substructure (piers and abutments) rates fair at 5/9, minor deterioration that routine maintenance should address.

How to read this record

C3057 is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare C3057 against other structures in Washington and across Vermont. Vermont bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for C3057?

C3057 in Washington, Vermont has a deck rating of 6/9, superstructure rating of 4/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is C3057 inspected?

C3057's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 150 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. C3057 is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for C3057?

C3057 has an NBI inventory load rating of 12.7 metric tons.

Who is responsible for maintaining C3057?

C3057 is owned and maintained by Railroad.

How old is C3057 and does age affect safety?

C3057 was built in 1908, making it 118 years old and last reconstructed in 1986.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.