FHWA NBI 2024 Inspection record Public-domain dataset

7334C

Carrying 7334C over YELLOW WATER DITCH

2.0E & 5.6S SH51B/104 INT, Wagoner, Oklahoma

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
18 t Inventory load rating

Bridge Snapshot: 7334C

The 7334C bridge in Wagoner, Oklahoma carries 7334C over YELLOW WATER DITCH. It was built in 1949, making it 77 years old today. The structure is built primarily of concrete and spans 3 sections, stretching 23.1 meters (76 feet) end to end. Daily traffic averages 200 vehicles, placing it in the lower-traffic tier of Oklahoma bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 4/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order. Its NBI inventory load rating is 18.2 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How 7334C compares

▼ 14.2
Load rating vs Oklahoma average (32.4 t)
Bottom 8%
Lower load rating than 92% of Oklahoma bridges
253
Bridges in Wagoner · 15 in Poor condition
7334C 18.2 t
Oklahoma average 32.4 t

Live comparison across Oklahoma.

Historical Sufficiency Rating

PlainBridge-computed
43.8 / 100 - historical 20–49.9 band
Structural adequacy /55
12.6
Serviceability /30
16.3
Essentiality /15
14.9
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
18.2 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1949
Material
Concrete
Number of Spans
3
Structure Length
23.1 m (76 ft)
Deck Width
7.5 m (25 ft)
Owner
County Highway Agency
Avg Daily Traffic
200 vehicles/day
Structure Number
110750000000000

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • At 6/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • The substructure (piers and abutments) is in poor condition (4/9), showing advanced deterioration that may require priority repair.

How to read this record

7334C is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare 7334C against other structures in Wagoner and across Oklahoma. Oklahoma bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for 7334C?

7334C in Wagoner, Oklahoma has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is 7334C inspected?

7334C's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 200 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. 7334C is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for 7334C?

7334C has an NBI inventory load rating of 18.2 metric tons.

Who is responsible for maintaining 7334C?

7334C is owned and maintained by County Highway Agency.

How old is 7334C and does age affect safety?

7334C was built in 1949, making it 77 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.