FHWA NBI 2024 Inspection record Public-domain dataset

CR 2126

Carrying CR 2126 over SIMS BRANCH

0.8 MI S OF FM 2663, Houston, Texas

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
14 t Inventory load rating

Bridge Snapshot: CR 2126

The CR 2126 bridge in Houston, Texas carries CR 2126 over SIMS BRANCH. It was built in 1990, making it 36 years old today. It was last reconstructed in 2021, extending its service life. The structure is built primarily of wood or timber and spans 1 section, stretching 8.8 meters (29 feet) end to end. Daily traffic averages 20 vehicles, placing it in the lower-traffic tier of Texas bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 8/9, superstructure at 7/9, substructure at 7/9. The weakest component sits in good condition. All reported major components score above the Poor range. Its NBI inventory load rating is 13.6 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How CR 2126 compares

▼ 14.7
Load rating vs Texas average (28.3 t)
Bottom 1%
Lower load rating than 99% of Texas bridges
196
Bridges in Houston · 14 in Poor condition
CR 2126 13.6 t
Texas average 28.3 t

Live comparison across Texas.

Historical Sufficiency Rating

PlainBridge-computed
43.0 / 100 - historical 20–49.9 band
Structural adequacy /55
28.5
Serviceability /30
8.0
Essentiality /15
14.6
Special reductions
−8.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
8/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
7/9
Good (7–9)
Inventory Load Rating
13.6 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1990
Last Reconstructed
2021
Material
Wood or Timber
Number of Spans
1
Structure Length
8.8 m (29 ft)
Deck Width
4.7 m (15 ft)
Owner
County Highway Agency
Avg Daily Traffic
20 vehicles/day
Structure Number
111140AA9803001

Condition Analysis

  • The deck (driving surface) is in good condition (8/9), showing no significant deterioration.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • At 7/9, the substructure (piers and abutments) is in good shape and shows no significant wear.

How to read this record

This page shows what the last federal inspection recorded, not whether CR 2126 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare CR 2126 against other structures in Houston and across Texas. Texas bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for CR 2126?

CR 2126 in Houston, Texas has a deck rating of 8/9, superstructure rating of 7/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is CR 2126 inspected?

CR 2126's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 20 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. CR 2126 is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for CR 2126?

CR 2126 has an NBI inventory load rating of 13.6 metric tons.

Who is responsible for maintaining CR 2126?

CR 2126 is owned and maintained by County Highway Agency.

How old is CR 2126 and does age affect safety?

CR 2126 was built in 1990, making it 36 years old and last reconstructed in 2021.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.