FHWA NBI 2024 Inspection record Public-domain dataset

ATHERTON-SIBLEY

Carrying ATHERTON-SIBLEY over LIT BLUE RVR

S 36 T 51 N R 31 W, Jackson, Missouri

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
22 t Inventory load rating

Bridge Snapshot: ATHERTON-SIBLEY

The ATHERTON-SIBLEY bridge in Jackson, Missouri carries ATHERTON-SIBLEY over LIT BLUE RVR. It was built in 1977, making it 49 years old today. The structure is built primarily of prestressed concrete and spans 5 sections, stretching 132.3 meters (434 feet) end to end. Daily traffic averages 135 vehicles, placing it in the lower-traffic tier of Missouri bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 7/9, substructure at 6/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 21.6 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How ATHERTON-SIBLEY compares

▼ 12.1
Load rating vs Missouri average (33.7 t)
Bottom 23%
Lower load rating than 77% of Missouri bridges
930
Bridges in Jackson · 43 in Poor condition
ATHERTON-SIBLEY 21.6 t
Missouri average 33.7 t

Live comparison across Missouri.

Historical Sufficiency Rating

PlainBridge-computed
82.3 / 100 - historical 80–100 band
Structural adequacy /55
43.5
Serviceability /30
24.0
Essentiality /15
14.9
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
7/9
Good (7–9)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
21.6 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1977
Material
Prestressed Concrete
Number of Spans
5
Structure Length
132.3 m (434 ft)
Deck Width
9.1 m (30 ft)
Owner
County Highway Agency
Avg Daily Traffic
135 vehicles/day
Structure Number
13839

Condition Analysis

  • The deck (driving surface) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • The superstructure (beams and supports above the deck) is in good condition (7/9), showing no significant deterioration.
  • The substructure (piers and abutments) rates fair at 6/9, minor deterioration that routine maintenance should address.

How to read this record

This page shows what the last federal inspection recorded, not whether ATHERTON-SIBLEY is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare ATHERTON-SIBLEY against other structures in Jackson and across Missouri. Missouri bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for ATHERTON-SIBLEY?

ATHERTON-SIBLEY in Jackson, Missouri has a deck rating of 5/9, superstructure rating of 7/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is ATHERTON-SIBLEY inspected?

ATHERTON-SIBLEY's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 135 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. ATHERTON-SIBLEY is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for ATHERTON-SIBLEY?

ATHERTON-SIBLEY has an NBI inventory load rating of 21.6 metric tons.

Who is responsible for maintaining ATHERTON-SIBLEY?

ATHERTON-SIBLEY is owned and maintained by County Highway Agency.

How old is ATHERTON-SIBLEY and does age affect safety?

ATHERTON-SIBLEY was built in 1977, making it 49 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.