FHWA NBI 2024 Inspection record Public-domain dataset

CAREY AV(CR 511NB)

Carrying CAREY AV(CR 511NB) over KIKEOUT BROOK

AT INT WITH BOONTON AVE, Morris, New Jersey

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
30 t Inventory load rating

Bridge Snapshot: CAREY AV(CR 511NB)

The CAREY AV(CR 511NB) bridge in Morris, New Jersey carries CAREY AV(CR 511NB) over KIKEOUT BROOK. It was built in 1928, making it 98 years old today. It was last reconstructed in 1966, extending its service life. The structure is built primarily of steel and spans 1 section, stretching 7.9 meters (26 feet) end to end. Daily traffic averages 5,101 vehicles, placing it in the moderately-trafficked tier of New Jersey bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 4/9, substructure at 5/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 29.9 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How CAREY AV(CR 511NB) compares

▼ 13.9
Load rating vs New Jersey average (43.8 t)
Bottom 26%
Lower load rating than 74% of New Jersey bridges
504
Bridges in Morris · 19 in Poor condition
CAREY AV(CR 511NB) 29.9 t
New Jersey average 43.8 t

Live comparison across New Jersey.

Historical Sufficiency Rating

PlainBridge-computed
69.0 / 100 - historical 50–79.9 band
Structural adequacy /55
28.7
Serviceability /30
26.0
Essentiality /15
14.3
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
4/9
Poor (1–4)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
29.9 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1928
Last Reconstructed
1966
Material
Steel
Number of Spans
1
Structure Length
7.9 m (26 ft)
Deck Width
14.1 m (46 ft)
Owner
County Highway Agency
Avg Daily Traffic
5,101 vehicles/day
Structure Number
1400132

Condition Analysis

  • At 5/9, the deck (driving surface) shows fair condition, with minor wear flagged for upkeep.
  • At 4/9, the superstructure (beams and supports above the deck) is in poor shape, with advanced wear flagged for priority repair.
  • The substructure (piers and abutments) is in fair condition (5/9), with minor deterioration that may require routine maintenance.

How to read this record

CAREY AV(CR 511NB) is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare CAREY AV(CR 511NB) against other structures in Morris and across New Jersey. New Jersey bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for CAREY AV(CR 511NB)?

CAREY AV(CR 511NB) in Morris, New Jersey has a deck rating of 5/9, superstructure rating of 4/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is CAREY AV(CR 511NB) inspected?

CAREY AV(CR 511NB)'s responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 5,101 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. CAREY AV(CR 511NB) is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for CAREY AV(CR 511NB)?

CAREY AV(CR 511NB) has an NBI inventory load rating of 29.9 metric tons.

Who is responsible for maintaining CAREY AV(CR 511NB)?

CAREY AV(CR 511NB) is owned and maintained by County Highway Agency.

How old is CAREY AV(CR 511NB) and does age affect safety?

CAREY AV(CR 511NB) was built in 1928, making it 98 years old and last reconstructed in 1966.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.