FHWA NBI 2024 Inspection record Public-domain dataset

NJ 124 EB

Carrying NJ 124 EB over PASSAIC RIVER

3.2 MILES WEST JCT 24&78, Morris, New Jersey

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
45 t Inventory load rating

Bridge Snapshot: NJ 124 EB

The NJ 124 EB bridge in Morris, New Jersey carries NJ 124 EB over PASSAIC RIVER. It was built in 1971, making it 55 years old today. The structure is built primarily of steel and spans 1 section, stretching 29.0 meters (95 feet) end to end. Daily traffic averages 6,579 vehicles, placing it in the moderately-trafficked tier of New Jersey bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 6/9, substructure at 6/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 44.5 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How NJ 124 EB compares

▲ 0.7
Load rating vs New Jersey average (43.8 t)
Top 40%
Higher load rating than 60% of New Jersey bridges
504
Bridges in Morris · 19 in Poor condition
NJ 124 EB 44.5 t
New Jersey average 43.8 t

Live comparison across New Jersey.

Historical Sufficiency Rating

PlainBridge-computed
90.3 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
23.0
Essentiality /15
14.3
Special reductions
−2.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
6/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
44.5 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1971
Material
Steel
Number of Spans
1
Structure Length
29.0 m (95 ft)
Deck Width
11.1 m (36 ft)
Owner
State Highway Agency
Avg Daily Traffic
6,579 vehicles/day
Structure Number
1406157

Condition Analysis

  • At 4/9, the deck (driving surface) is in poor shape, with advanced wear flagged for priority repair.
  • The superstructure (beams and supports above the deck) rates fair at 6/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) rates fair at 6/9, minor deterioration that routine maintenance should address.

How to read this record

NJ 124 EB is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare NJ 124 EB against other structures in Morris and across New Jersey. New Jersey bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for NJ 124 EB?

NJ 124 EB in Morris, New Jersey has a deck rating of 4/9, superstructure rating of 6/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is NJ 124 EB inspected?

NJ 124 EB's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 6,579 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. NJ 124 EB is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for NJ 124 EB?

NJ 124 EB has an NBI inventory load rating of 44.5 metric tons.

Who is responsible for maintaining NJ 124 EB?

NJ 124 EB is owned and maintained by State Highway Agency.

How old is NJ 124 EB and does age affect safety?

NJ 124 EB was built in 1971, making it 55 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.