Fair
26 t Inventory load rating

Bridge Snapshot: BUENA VISTA ST

The BUENA VISTA ST bridge in Bexar, Texas carries BUENA VISTA ST over ALAZAN CREEK. It was built in 1963, making it 63 years old today. The structure is built primarily of concrete continuous and spans 4 sections, stretching 55.5 meters (182 feet) end to end. Daily traffic averages 7,580 vehicles, placing it in the moderately-trafficked tier of Texas bridges. It is owned and maintained by City/Municipal Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 6/9, substructure at 7/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 26.3 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How BUENA VISTA ST compares

▼ 2.0
Load rating vs Texas average (28.3 t)
Top 48%
Higher load rating than 52% of Texas bridges
2,343
Bridges in Bexar · 5 in Poor condition
BUENA VISTA ST 26.3 t
Texas average 28.3 t

Live comparison across Texas.

Historical Sufficiency Rating

PlainBridge-computed
74.1 / 100 - historical 50–79.9 band
Structural adequacy /55
50.1
Serviceability /30
13.0
Essentiality /15
14.0
Special reductions
−3.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
6/9
Fair (5–6)
Substructure
7/9
Good (7–9)
Inventory Load Rating
26.3 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1963
Material
Concrete Continuous
Number of Spans
4
Structure Length
55.5 m (182 ft)
Deck Width
15.7 m (52 ft)
Owner
City/Municipal Highway Agency
Avg Daily Traffic
7,580 vehicles/day
Structure Number
150150B04695001

Condition Analysis

  • The deck (driving surface) is in good condition (7/9), showing no significant deterioration.
  • At 6/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • The substructure (piers and abutments) rates good at 7/9, with no significant deterioration on file.

How to read this record

This page shows what the last federal inspection recorded, not whether BUENA VISTA ST is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare BUENA VISTA ST against other structures in Bexar and across Texas. Texas bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for BUENA VISTA ST?

BUENA VISTA ST in Bexar, Texas has a deck rating of 7/9, superstructure rating of 6/9, and substructure rating of 7/9 on the FHWA's 0–9 scale.

How often is BUENA VISTA ST inspected?

BUENA VISTA ST's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 7,580 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. BUENA VISTA ST is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for BUENA VISTA ST?

BUENA VISTA ST has an NBI inventory load rating of 26.3 metric tons.

Who is responsible for maintaining BUENA VISTA ST?

BUENA VISTA ST is owned and maintained by City/Municipal Highway Agency.

How old is BUENA VISTA ST and does age affect safety?

BUENA VISTA ST was built in 1963, making it 63 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.