FHWA NBI 2024 Inspection record Public-domain dataset

FAS 2306

Carrying FAS 2306 over SIXTEEN MILE CREEK

2.3 N. OF FARGO, Ellis, Oklahoma

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
19 t Inventory load rating

Bridge Snapshot: FAS 2306

The FAS 2306 bridge in Ellis, Oklahoma carries FAS 2306 over SIXTEEN MILE CREEK. It was built in 1974, making it 52 years old today. The structure is built primarily of concrete and spans 3 sections, stretching 36.6 meters (120 feet) end to end. Daily traffic averages 155 vehicles, placing it in the lower-traffic tier of Oklahoma bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 6/9, superstructure at 6/9, substructure at 6/9. The weakest component sits in fair condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 19.1 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How FAS 2306 compares

▼ 13.3
Load rating vs Oklahoma average (32.4 t)
Bottom 9%
Lower load rating than 91% of Oklahoma bridges
152
Bridges in Ellis
FAS 2306 19.1 t
Oklahoma average 32.4 t

Live comparison across Oklahoma.

Historical Sufficiency Rating

PlainBridge-computed
83.1 / 100 - historical 80–100 band
Structural adequacy /55
39.2
Serviceability /30
29.0
Essentiality /15
14.9
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
6/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
19.1 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1974
Material
Concrete
Number of Spans
3
Structure Length
36.6 m (120 ft)
Deck Width
9.4 m (31 ft)
Owner
County Highway Agency
Avg Daily Traffic
155 vehicles/day
Structure Number
187160000000000

Condition Analysis

  • The deck (driving surface) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The superstructure (beams and supports above the deck) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) rates fair at 6/9, minor deterioration that routine maintenance should address.

How to read this record

This page shows what the last federal inspection recorded, not whether FAS 2306 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare FAS 2306 against other structures in Ellis and across Oklahoma. Oklahoma bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for FAS 2306?

FAS 2306 in Ellis, Oklahoma has a deck rating of 6/9, superstructure rating of 6/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is FAS 2306 inspected?

FAS 2306's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 155 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. FAS 2306 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for FAS 2306?

FAS 2306 has an NBI inventory load rating of 19.1 metric tons.

Who is responsible for maintaining FAS 2306?

FAS 2306 is owned and maintained by County Highway Agency.

How old is FAS 2306 and does age affect safety?

FAS 2306 was built in 1974, making it 52 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.