FHWA NBI 2024 Inspection record Public-domain dataset

HIESTAND

Carrying HIESTAND over NORTHFORKSTILLWATER RIVE

.31 MI E RHYNARD-FINK, Darke, Ohio

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
26 t Inventory load rating

Bridge Snapshot: HIESTAND

The HIESTAND bridge in Darke, Ohio carries HIESTAND over NORTHFORKSTILLWATER RIVE. It was built in 1954, making it 72 years old today. The structure is built primarily of concrete and spans 1 section, stretching 12.8 meters (42 feet) end to end. Daily traffic averages 351 vehicles, placing it in the lower-traffic tier of Ohio bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 6/9, substructure at 6/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range. Its NBI inventory load rating is 25.9 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How HIESTAND compares

▼ 11.6
Load rating vs Ohio average (37.5 t)
Bottom 13%
Lower load rating than 87% of Ohio bridges
463
Bridges in Darke · 2 in Poor condition
HIESTAND 25.9 t
Ohio average 37.5 t

Live comparison across Ohio.

Historical Sufficiency Rating

PlainBridge-computed
90.5 / 100 - historical 80–100 band
Structural adequacy /55
49.6
Serviceability /30
26.0
Essentiality /15
14.9
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
6/9
Fair (5–6)
Substructure
6/9
Fair (5–6)
Inventory Load Rating
25.9 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1954
Material
Concrete
Number of Spans
1
Structure Length
12.8 m (42 ft)
Deck Width
6.9 m (23 ft)
Owner
County Highway Agency
Avg Daily Traffic
351 vehicles/day
Structure Number
1953893

Condition Analysis

  • The deck (driving surface) rates good at 7/9, with no significant deterioration on file.
  • The superstructure (beams and supports above the deck) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • The substructure (piers and abutments) is in fair condition (6/9), with minor deterioration that may require routine maintenance.

How to read this record

This page shows what the last federal inspection recorded, not whether HIESTAND is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare HIESTAND against other structures in Darke and across Ohio. Ohio bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for HIESTAND?

HIESTAND in Darke, Ohio has a deck rating of 7/9, superstructure rating of 6/9, and substructure rating of 6/9 on the FHWA's 0–9 scale.

How often is HIESTAND inspected?

HIESTAND's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 351 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. HIESTAND is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for HIESTAND?

HIESTAND has an NBI inventory load rating of 25.9 metric tons.

Who is responsible for maintaining HIESTAND?

HIESTAND is owned and maintained by County Highway Agency.

How old is HIESTAND and does age affect safety?

HIESTAND was built in 1954, making it 72 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.