Good
44 t Inventory load rating

Bridge Snapshot: VT 00110 ML

The VT 00110 ML bridge in Orange, Vermont carries VT 00110 ML over 1ST BRANCH WHITE R.. It was built in 2007, making it 19 years old today. The structure is built primarily of steel continuous and spans 2 sections, stretching 56.1 meters (184 feet) end to end. Daily traffic averages 1,700 vehicles, placing it in the moderately-trafficked tier of Vermont bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 8/9, superstructure at 8/9, substructure at 8/9. The weakest component sits in good condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 43.5 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How VT 00110 ML compares

▲ 6.8
Load rating vs Vermont average (36.7 t)
Top 31%
Higher load rating than 69% of Vermont bridges
210
Bridges in Orange · 4 in Poor condition
VT 00110 ML 43.5 t
Vermont average 36.7 t

Live comparison across Vermont.

Historical Sufficiency Rating

PlainBridge-computed
77.6 / 100 - historical 50–79.9 band
Structural adequacy /55
55.0
Serviceability /30
13.6
Essentiality /15
9.1
Special reductions
−0.1

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
8/9
Good (7–9)
Superstructure
8/9
Good (7–9)
Substructure
8/9
Good (7–9)
Inventory Load Rating
43.5 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
2007
Material
Steel Continuous
Number of Spans
2
Structure Length
56.1 m (184 ft)
Deck Width
10.9 m (36 ft)
Owner
State Highway Agency
Avg Daily Traffic
1,700 vehicles/day
Structure Number
200169000409132

Condition Analysis

  • At 8/9, the deck (driving surface) is in good shape and shows no significant wear.
  • The superstructure (beams and supports above the deck) rates good at 8/9, with no significant deterioration on file.
  • The substructure (piers and abutments) is in good condition (8/9), showing no significant deterioration.

How to read this record

This page shows what the last federal inspection recorded, not whether VT 00110 ML is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare VT 00110 ML against other structures in Orange and across Vermont. Vermont bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for VT 00110 ML?

VT 00110 ML in Orange, Vermont has a deck rating of 8/9, superstructure rating of 8/9, and substructure rating of 8/9 on the FHWA's 0–9 scale.

How often is VT 00110 ML inspected?

VT 00110 ML's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 1,700 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. VT 00110 ML is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for VT 00110 ML?

VT 00110 ML has an NBI inventory load rating of 43.5 metric tons.

Who is responsible for maintaining VT 00110 ML?

VT 00110 ML is owned and maintained by State Highway Agency.

How old is VT 00110 ML and does age affect safety?

VT 00110 ML was built in 2007, making it 19 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.