FHWA NBI 2024 Inspection record Public-domain dataset

TR 01 FAS 177

Carrying TR 01 FAS 177 over W BR. OMPOMPANOOSUC RIV.

5.8 MI W JCT. US 5, Orange, Vermont

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Good
33 t Inventory load rating

Bridge Snapshot: TR 01 FAS 177

The TR 01 FAS 177 bridge in Orange, Vermont carries TR 01 FAS 177 over W BR. OMPOMPANOOSUC RIV.. It was built in 1946, making it 80 years old today. It was last reconstructed in 2012, extending its service life. The structure is built primarily of steel continuous and spans 3 sections, stretching 68.6 meters (225 feet) end to end. Daily traffic averages 890 vehicles, placing it in the lower-traffic tier of Vermont bridges. It is owned and maintained by Town/Township Highway Agency.

The latest FHWA inspection records show a deck rating of 8/9, superstructure at 8/9, substructure at 8/9. The weakest component sits in good condition. No reported major component scores in the Poor range under the current federal condition thresholds. Its NBI inventory load rating is 32.7 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How TR 01 FAS 177 compares

▼ 4.0
Load rating vs Vermont average (36.7 t)
Bottom 36%
Lower load rating than 64% of Vermont bridges
210
Bridges in Orange · 4 in Poor condition
TR 01 FAS 177 32.7 t
Vermont average 36.7 t

Live comparison across Vermont.

Historical Sufficiency Rating

PlainBridge-computed
82.6 / 100 - historical 80–100 band
Structural adequacy /55
55.0
Serviceability /30
14.9
Essentiality /15
12.7
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
8/9
Good (7–9)
Superstructure
8/9
Good (7–9)
Substructure
8/9
Good (7–9)
Inventory Load Rating
32.7 t
NBI inventory level (metric tons)
Overall Condition
Good

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1946
Last Reconstructed
2012
Material
Steel Continuous
Number of Spans
3
Structure Length
68.6 m (225 ft)
Deck Width
8.4 m (28 ft)
Owner
Town/Township Highway Agency
Avg Daily Traffic
890 vehicles/day
Structure Number
200177000809112

Condition Analysis

  • The deck (driving surface) rates good at 8/9, with no significant deterioration on file.
  • The superstructure (beams and supports above the deck) is in good condition (8/9), showing no significant deterioration.
  • The substructure (piers and abutments) rates good at 8/9, with no significant deterioration on file.

How to read this record

This page shows what the last federal inspection recorded, not whether TR 01 FAS 177 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare TR 01 FAS 177 against other structures in Orange and across Vermont. Vermont bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for TR 01 FAS 177?

TR 01 FAS 177 in Orange, Vermont has a deck rating of 8/9, superstructure rating of 8/9, and substructure rating of 8/9 on the FHWA's 0–9 scale.

How often is TR 01 FAS 177 inspected?

TR 01 FAS 177's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 890 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. TR 01 FAS 177 is currently shown as Good condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for TR 01 FAS 177?

TR 01 FAS 177 has an NBI inventory load rating of 32.7 metric tons.

Who is responsible for maintaining TR 01 FAS 177?

TR 01 FAS 177 is owned and maintained by Town/Township Highway Agency.

How old is TR 01 FAS 177 and does age affect safety?

TR 01 FAS 177 was built in 1946, making it 80 years old and last reconstructed in 2012.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.