FHWA NBI 2024 Inspection record Public-domain dataset

VT 00014 ML

Carrying VT 00014 ML over BLACK RIVER

0.7 MI S JCT. U.S.5 S, Orleans, Vermont

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
45 t Inventory load rating

Bridge Snapshot: VT 00014 ML

The VT 00014 ML bridge in Orleans, Vermont carries VT 00014 ML over BLACK RIVER. It was built in 2001, making it 25 years old today. The structure is built primarily of steel and spans 1 section, stretching 41.5 meters (136 feet) end to end. Daily traffic averages 1,700 vehicles, placing it in the moderately-trafficked tier of Vermont bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 3/9, superstructure at 0/9, substructure at 3/9. The weakest component sits in critical condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order. Its NBI inventory load rating is 44.5 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How VT 00014 ML compares

▲ 7.8
Load rating vs Vermont average (36.7 t)
Top 30%
Higher load rating than 70% of Vermont bridges
188
Bridges in Orleans · 5 in Poor condition
VT 00014 ML 44.5 t
Vermont average 36.7 t

Live comparison across Vermont.

Historical Sufficiency Rating

PlainBridge-computed
21.2 / 100 - historical 20–49.9 band
Structural adequacy /55
0.0
Serviceability /30
11.9
Essentiality /15
9.3
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
3/9
Poor (1–4)
Superstructure
0/9
Failed (0)
Substructure
3/9
Poor (1–4)
Inventory Load Rating
44.5 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
2001
Material
Steel
Number of Spans
1
Structure Length
41.5 m (136 ft)
Deck Width
9.5 m (31 ft)
Owner
State Highway Agency
Avg Daily Traffic
1,700 vehicles/day
Structure Number
200251012910112

Condition Analysis

  • The deck (driving surface) is in poor condition (3/9), showing advanced deterioration that may require priority repair.
  • At 0/9, the superstructure (beams and supports above the deck) is in critical shape, with severe wear requiring urgent action.
  • The substructure (piers and abutments) rates poor at 3/9, advanced deterioration that should be prioritized for repair.

How to read this record

VT 00014 ML is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare VT 00014 ML against other structures in Orleans and across Vermont. Vermont bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for VT 00014 ML?

VT 00014 ML in Orleans, Vermont has a deck rating of 3/9, superstructure rating of 0/9, and substructure rating of 3/9 on the FHWA's 0–9 scale.

How often is VT 00014 ML inspected?

VT 00014 ML's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 1,700 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. VT 00014 ML is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for VT 00014 ML?

VT 00014 ML has an NBI inventory load rating of 44.5 metric tons.

Who is responsible for maintaining VT 00014 ML?

VT 00014 ML is owned and maintained by State Highway Agency.

How old is VT 00014 ML and does age affect safety?

VT 00014 ML was built in 2001, making it 25 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.