FHWA NBI 2024 Inspection record Public-domain dataset

SH 73 EB

Carrying SH 73 EB over KCS RAILROAD

0.50 MI NW OF SH 347, Jefferson, Texas

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
38 t Inventory load rating

Bridge Snapshot: SH 73 EB

The SH 73 EB bridge in Jefferson, Texas carries SH 73 EB over KCS RAILROAD. It was built in 1968, making it 58 years old today. The structure is built primarily of prestressed concrete and spans 2 sections, stretching 125.0 meters (410 feet) end to end. Daily traffic averages 13,645 vehicles, placing it in the heavily-trafficked tier of Texas bridges. It is owned and maintained by State Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 5/9, substructure at 4/9. The weakest component sits in poor condition. Because at least one major component scores 4 or lower, this bridge falls in FHWA's Poor condition category. That category is not a closure order. Its NBI inventory load rating is 38.1 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How SH 73 EB compares

▲ 9.8
Load rating vs Texas average (28.3 t)
Top 7%
Higher load rating than 93% of Texas bridges
457
Bridges in Jefferson · 6 in Poor condition
SH 73 EB 38.1 t
Texas average 28.3 t

Live comparison across Texas.

Historical Sufficiency Rating

PlainBridge-computed
67.0 / 100 - historical 50–79.9 band
Structural adequacy /55
30.0
Serviceability /30
25.0
Essentiality /15
13.0
Special reductions
−1.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
5/9
Fair (5–6)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
38.1 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1968
Material
Prestressed Concrete
Number of Spans
2
Structure Length
125.0 m (410 ft)
Deck Width
15.3 m (50 ft)
Owner
State Highway Agency
Avg Daily Traffic
13,645 vehicles/day
Structure Number
201240050804201

Condition Analysis

  • The deck (driving surface) is in fair condition (5/9), with minor deterioration that may require routine maintenance.
  • The superstructure (beams and supports above the deck) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • The substructure (piers and abutments) is in poor condition (4/9), showing advanced deterioration that may require priority repair.

How to read this record

SH 73 EB is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare SH 73 EB against other structures in Jefferson and across Texas. Texas bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for SH 73 EB?

SH 73 EB in Jefferson, Texas has a deck rating of 5/9, superstructure rating of 5/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is SH 73 EB inspected?

SH 73 EB's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 13,645 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. SH 73 EB is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for SH 73 EB?

SH 73 EB has an NBI inventory load rating of 38.1 metric tons.

Who is responsible for maintaining SH 73 EB?

SH 73 EB is owned and maintained by State Highway Agency.

How old is SH 73 EB and does age affect safety?

SH 73 EB was built in 1968, making it 58 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.