FHWA NBI 2024 Inspection record Public-domain dataset

N3520

Carrying N3520 over HORSE CREEK

1.N 1.2E 1.5N OF AVERY, Lincoln, Oklahoma

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Fair
45 t Inventory load rating

Bridge Snapshot: N3520

The N3520 bridge in Lincoln, Oklahoma carries N3520 over HORSE CREEK. It was built in 1984, making it 42 years old today. The structure is built primarily of prestressed concrete and spans 1 section, stretching 27.4 meters (90 feet) end to end. Daily traffic averages 100 vehicles, placing it in the lower-traffic tier of Oklahoma bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 6/9, substructure at 5/9. The weakest component sits in fair condition. None of this bridge's reported major components fall into the Poor condition range. Its NBI inventory load rating is 44.5 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How N3520 compares

▲ 12.1
Load rating vs Oklahoma average (32.4 t)
Top 14%
Higher load rating than 86% of Oklahoma bridges
448
Bridges in Lincoln · 60 in Poor condition
N3520 44.5 t
Oklahoma average 32.4 t

Live comparison across Oklahoma.

Historical Sufficiency Rating

PlainBridge-computed
76.2 / 100 - historical 50–79.9 band
Structural adequacy /55
45.0
Serviceability /30
18.3
Essentiality /15
15.0
Special reductions
−2.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
6/9
Fair (5–6)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
44.5 t
NBI inventory level (metric tons)
Overall Condition
Fair

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1984
Material
Prestressed Concrete
Number of Spans
1
Structure Length
27.4 m (90 ft)
Deck Width
7.2 m (24 ft)
Owner
County Highway Agency
Avg Daily Traffic
100 vehicles/day
Structure Number
207830000000000

Condition Analysis

  • At 7/9, the deck (driving surface) is in good shape and shows no significant wear.
  • The superstructure (beams and supports above the deck) is in fair condition (6/9), with minor deterioration that may require routine maintenance.
  • At 5/9, the substructure (piers and abutments) shows fair condition, with minor wear flagged for upkeep.

How to read this record

This page shows what the last federal inspection recorded, not whether N3520 is safe to cross today. Here is how to use it.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Learn how the 0–9 condition scale and Good/Fair/Poor categories are defined. How condition ratings work
  • Compare N3520 against other structures in Lincoln and across Oklahoma. Oklahoma bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for N3520?

N3520 in Lincoln, Oklahoma has a deck rating of 7/9, superstructure rating of 6/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is N3520 inspected?

N3520's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 100 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. N3520 is currently shown as Fair condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for N3520?

N3520 has an NBI inventory load rating of 44.5 metric tons.

Who is responsible for maintaining N3520?

N3520 is owned and maintained by County Highway Agency.

How old is N3520 and does age affect safety?

N3520 was built in 1984, making it 42 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.