FHWA NBI 2024 Inspection record Public-domain dataset

2690C

Carrying 2690C over CREEK

4 MI S 1.8 E VERDEN, Grady, Oklahoma

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
45 t Inventory load rating

Bridge Snapshot: 2690C

The 2690C bridge in Grady, Oklahoma carries 2690C over CREEK. It was built in 1986, making it 40 years old today. The structure is built primarily of prestressed concrete and spans 1 section, stretching 19.1 meters (63 feet) end to end. Daily traffic averages 180 vehicles, placing it in the lower-traffic tier of Oklahoma bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 7/9, superstructure at 7/9, substructure at 4/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 44.5 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How 2690C compares

▲ 12.1
Load rating vs Oklahoma average (32.4 t)
Top 14%
Higher load rating than 86% of Oklahoma bridges
446
Bridges in Grady · 31 in Poor condition
2690C 44.5 t
Oklahoma average 32.4 t

Live comparison across Oklahoma.

Historical Sufficiency Rating

PlainBridge-computed
68.9 / 100 - historical 50–79.9 band
Structural adequacy /55
30.0
Serviceability /30
27.0
Essentiality /15
14.9
Special reductions
−3.0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
7/9
Good (7–9)
Superstructure
7/9
Good (7–9)
Substructure
4/9
Poor (1–4)
Inventory Load Rating
44.5 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1986
Material
Prestressed Concrete
Number of Spans
1
Structure Length
19.1 m (63 ft)
Deck Width
8.7 m (29 ft)
Owner
County Highway Agency
Avg Daily Traffic
180 vehicles/day
Structure Number
212790000000000

Condition Analysis

  • At 7/9, the deck (driving surface) is in good shape and shows no significant wear.
  • At 7/9, the superstructure (beams and supports above the deck) is in good shape and shows no significant wear.
  • The substructure (piers and abutments) is in poor condition (4/9), showing advanced deterioration that may require priority repair.

How to read this record

2690C is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare 2690C against other structures in Grady and across Oklahoma. Oklahoma bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for 2690C?

2690C in Grady, Oklahoma has a deck rating of 7/9, superstructure rating of 7/9, and substructure rating of 4/9 on the FHWA's 0–9 scale.

How often is 2690C inspected?

2690C's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 180 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. 2690C is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for 2690C?

2690C has an NBI inventory load rating of 44.5 metric tons.

Who is responsible for maintaining 2690C?

2690C is owned and maintained by County Highway Agency.

How old is 2690C and does age affect safety?

2690C was built in 1986, making it 40 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.