FHWA NBI 2024 Inspection record Public-domain dataset

TITAN LN

Carrying TITAN LN over BNSF RR

S 23 T 61 N R 14 W, Adair, Missouri

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
12 t Inventory load rating

Bridge Snapshot: TITAN LN

The TITAN LN bridge in Adair, Missouri carries TITAN LN over BNSF RR. It was built in 1950, making it 76 years old today. The structure is built primarily of steel and spans 1 section, stretching 38.1 meters (125 feet) end to end. Daily traffic averages 5 vehicles, placing it in the lower-traffic tier of Missouri bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 4/9, superstructure at 3/9, substructure at 5/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 11.7 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How TITAN LN compares

▼ 22.0
Load rating vs Missouri average (33.7 t)
Bottom 6%
Lower load rating than 94% of Missouri bridges
301
Bridges in Adair · 20 in Poor condition
TITAN LN 11.7 t
Missouri average 33.7 t

Live comparison across Missouri.

Historical Sufficiency Rating

PlainBridge-computed
32.0 / 100 - historical 20–49.9 band
Structural adequacy /55
0.0
Serviceability /30
17.0
Essentiality /15
15.0
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
4/9
Poor (1–4)
Superstructure
3/9
Poor (1–4)
Substructure
5/9
Fair (5–6)
Inventory Load Rating
11.7 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1950
Material
Steel
Number of Spans
1
Structure Length
38.1 m (125 ft)
Deck Width
5.9 m (19 ft)
Owner
County Highway Agency
Avg Daily Traffic
5 vehicles/day
Structure Number
21632

Condition Analysis

  • The deck (driving surface) rates poor at 4/9, advanced deterioration that should be prioritized for repair.
  • The superstructure (beams and supports above the deck) is in poor condition (3/9), showing advanced deterioration that may require priority repair.
  • The substructure (piers and abutments) is in fair condition (5/9), with minor deterioration that may require routine maintenance.

How to read this record

TITAN LN is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare TITAN LN against other structures in Adair and across Missouri. Missouri bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for TITAN LN?

TITAN LN in Adair, Missouri has a deck rating of 4/9, superstructure rating of 3/9, and substructure rating of 5/9 on the FHWA's 0–9 scale.

How often is TITAN LN inspected?

TITAN LN's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 5 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. TITAN LN is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for TITAN LN?

TITAN LN has an NBI inventory load rating of 11.7 metric tons.

Who is responsible for maintaining TITAN LN?

TITAN LN is owned and maintained by County Highway Agency.

How old is TITAN LN and does age affect safety?

TITAN LN was built in 1950, making it 76 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.