FHWA NBI 2024 Inspection record Public-domain dataset

E 337 LN

Carrying E 337 LN over THOMPSON RVR TRIB

S 35 T 64 N R 26 W, Harrison, Missouri

Data updated May 2026

FHWA NBI record, refreshed with each annual release.

Poor
21 t Inventory load rating

Bridge Snapshot: E 337 LN

The E 337 LN bridge in Harrison, Missouri carries E 337 LN over THOMPSON RVR TRIB. It was built in 1986, making it 40 years old today. The structure is built primarily of steel and spans 1 section, stretching 14.9 meters (49 feet) end to end. Daily traffic averages 5 vehicles, placing it in the lower-traffic tier of Missouri bridges. It is owned and maintained by County Highway Agency.

The latest FHWA inspection records show a deck rating of 5/9, superstructure at 6/9, substructure at 3/9. The weakest component sits in poor condition. At least one major component here scores 4 or below, which produces a Poor condition classification under FHWA's current reporting rules. Its NBI inventory load rating is 20.7 metric tons.

Sourced from the FHWA National Bridge Inventory. See our methodology for refresh cadence and NBI release vintage.

How E 337 LN compares

▼ 13.0
Load rating vs Missouri average (33.7 t)
Bottom 22%
Lower load rating than 78% of Missouri bridges
331
Bridges in Harrison · 68 in Poor condition
E 337 LN 20.7 t
Missouri average 33.7 t

Live comparison across Missouri.

Historical Sufficiency Rating

PlainBridge-computed
28.4 / 100 - historical 20–49.9 band
Structural adequacy /55
2.0
Serviceability /30
11.7
Essentiality /15
14.7
Special reductions
0

FHWA discontinued this calculated item; it does not determine current condition, funding eligibility, posting, or closure. How the historical reference is calculated.

Condition Ratings

Deck
5/9
Fair (5–6)
Superstructure
6/9
Fair (5–6)
Substructure
3/9
Poor (1–4)
Inventory Load Rating
20.7 t
NBI inventory level (metric tons)
Overall Condition
Poor

Full 0–9 scale + sufficiency-rating breakdown: how condition ratings work.

Structural Details

Year Built
1986
Material
Steel
Number of Spans
1
Structure Length
14.9 m (49 ft)
Deck Width
4.9 m (16 ft)
Owner
County Highway Agency
Avg Daily Traffic
5 vehicles/day
Structure Number
21992

Condition Analysis

  • The deck (driving surface) rates fair at 5/9, minor deterioration that routine maintenance should address.
  • At 6/9, the superstructure (beams and supports above the deck) shows fair condition, with minor wear flagged for upkeep.
  • At 3/9, the substructure (piers and abutments) is in poor shape, with advanced wear flagged for priority repair.

How to read this record

E 337 LN is in the federal Poor condition category. That is a component-based result, not a closure order.

  • NBI condition ratings reflect the latest record in this annual dataset, not a live status. Current routine inspection intervals are risk-based.
  • Understand what Poor condition does and does not mean before drawing conclusions. Poor condition explained
  • Compare E 337 LN against other structures in Harrison and across Missouri. Missouri bridges
  • Noticed visible damage or a safety concern? Report it to the agency that owns the bridge, or call 911 in an emergency. How to report a bridge

Condition codes come straight from the FHWA National Bridge Inventory and are not a real-time safety judgment. Only the owning agency, a state DOT, county, or other owner, can post, restrict, or close a bridge.

Frequently Asked Questions

What do the condition ratings mean for E 337 LN?

E 337 LN in Harrison, Missouri has a deck rating of 5/9, superstructure rating of 6/9, and substructure rating of 3/9 on the FHWA's 0–9 scale.

How often is E 337 LN inspected?

E 337 LN's responsible agency sets its routine interval under FHWA's risk-based inspection rules; this page does not expose the scheduled interval. It carries about 5 vehicles per day.

What does “structurally deficient” mean in older bridge reports?

FHWA retired that reported status beginning with the 2018 archive. E 337 LN is currently shown as Poor condition from its component ratings; that category is not a live closure or safety decision.

What is the inventory load rating for E 337 LN?

E 337 LN has an NBI inventory load rating of 20.7 metric tons.

Who is responsible for maintaining E 337 LN?

E 337 LN is owned and maintained by County Highway Agency.

How old is E 337 LN and does age affect safety?

E 337 LN was built in 1986, making it 40 years old.

Disclaimer: Bridge condition data is from the FHWA NBI and reflects the last reported inspection. A Poor condition rating is not a live declaration that a bridge is closed or unsafe for travel. For current closure, posting, or safety information, contact the responsible transportation agency.

Data sourced from the Federal Highway Administration National Bridge Inventory. See our methodology for details. Retrieved and formatted by PlainBridges

Every figure on PlainBridge is rendered directly from federal source data, no number is typed in by an editor. This page draws directly on federal source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.